Leading Manufacturer of Safety Interlock Switches and Machine Guard Safety Switch Devices for Automation and Process Safety

Guard Locking RFID Safety Switch with OSSD up to 3000N (KL3-SS-Z)

The KL3-SS-Z guard locking RFID safety interlock with OSSD outputs, features a slimline stainless steel body profile for 50mm frames to enable easy retrofitting to new or existing guards. The robust design allows for a holding force of up to 3000N to keep medium to large guard doors closed until the hazard/s have been removed.

  • Material: Mirror Polished 316 Stainless Steel
  • Ingress Protection: IP69K
  • RFID Coding: Unique RFID Coding: (M) can be retaught (U) cannot be retaught
  • Safety Configuration: 2 OSSD Outputs and 2 Auxiliary Outputs
  • Holding Force: F1Max 3000N (300Kg)
  • Connection: 3 x M20 or ½” NPT (Quick Connect is Available)

NOTE: Suitable for Splash Zones in accordance with EHEDG guidelines.

Part No. Part Description
456001AZ KL3-SS-Z M20 (manual release lid and side) – Std Actuator
456001HFZ KL3-SS-Z M20 (manual release lid and side) – Heavy Duty Actuator
456002AZ KL3-SS-Z ½NPT (manual release lid and side) – Std Actuator
456002HFZ KL3-SS-Z ½NPT (manual release lid and side) – Heavy Duty Actuator
456003AZ KL3-SS-Z QC-M12 (manual release lid and side) – Std Actuator
456003HFZ KL3-SS-Z QC-M12 (manual release lid and side) – Heavy Duty Actuator
456301AZ KL3-SS-Z M20 (no release) – Std Actuator
456301HFZ KL3-SS-Z M20 (no release) – Heavy Duty Actuator
456302AZ KL3-SS-Z ½NPT (no release) – Std Actuator
456302HFZ KL3-SS-Z ½NPT (no release) – Heavy Duty Actuator
456303AZ KL3-SS-Z QC-M12 (no release) – Std Actuator
456303HFZ KL3-SS-Z QC-M12 (no release) – Heavy Duty Actuator
456401AZ KL3-SS-Z M20 (lid only release) – Std Actuator
456401HFZ KL3-SS-Z M20 (lid only release) – Heavy Duty Actuator
456402AZ KL3-SS-Z ½NPT (lid only release) – Std Actuator
456402HFZ KL3-SS-Z ½NPT (lid only release) – Heavy Duty Actuator
456403AZ KL3-SS-Z QC-M12 (lid only release) – Std Actuator
456403HFZ KL3-SS-Z QC-M12 (lid only release) – Heavy Duty Actuator
456011AZ KL3-SS-Z-RR M20 (manual release lid and side) – Std Actuator
456011HFZ KL3-SS-Z-RR M20 (manual release lid and side) – Heavy Duty Actuator
456012AZ KL3-SS-Z-RR ½NPT (manual release lid and side) – Std Actuator
456013AZ KL3-SS-Z-RR QC-M12 (manual release lid and side) – Std Actuator
456012HFZ KL3-SS-Z-RR ½NPT (manual release lid and side) – Heavy Duty Actuator
456013HFZ KL3-SS-Z-RR QC-M1 (manual release lid and side)2 – Heavy Duty Actuator
456311AZ KL3-SS-Z-RR M20 (no release) – Std Actuator
456311HFZ KL3-SS-Z-RR M20 (no release) – Heavy Duty Actuator
456312AZ KL3-SS-Z-RR ½NPT (no release) – Std Actuator
456312HFZ KL3-SS-Z-RR ½NPT (no release) – Heavy Duty Actuator
456313AZ KL3-SS-Z-RR QC-M12 (no release) – Std Actuator
456313HFZ KL3-SS-Z-RR QC-M12 (no release) – Heavy Duty Actuator
456411AZ KL3-SS-Z-RR M20 (lid only release) – Std Actuator
456411HFZ KL3-SS-Z-RR M20 (lid only release) – Heavy Duty Actuator
456412AZ KL3-SS-Z-RR ½NPT (lid only release) – Std Actuator
456412HFZ KL3-SS-Z-RR ½NPT (lid only release) – Heavy Duty Actuator
456413AZ KL3-SS-Z-RR QC-M12 (lid only release) – Std Actuator
456413HFZ KL3-SS-Z-RR QC-M12 (lid only release) – Heavy Duty Actuator

Technical Data
ApprovalsTUV, cULus
Classification and Coding Level according to EN ISO 14119Type 4, High
TechnologyRFID, Power to Unlock
Housing Material 316 Grade Stainless Steel
Supply Voltage24Vdc (+/- 10%) SELV/PELV or Class 2
Power ConsumptionR+ (50mA Max.) / S+ (500mA Max.) (Solenoid)
Safety Circuits2 OSSD PNP Outputs (24Vdc 200mA max. switching)
Auxiliary Circuits (34 & 44)24Vdc 200mA max. Output feed
Rated Insulation Voltage500VAC
Rated Impulse withstand1000VAC
Holding Force (ISO14119)F1Max 3000N Fzh 2307N
Actuator insertion for locking5mm
Sao / Sar (RFID)15mm / 25mm
Operating Frequency1Hz
Actuator entry minimum radius175mm
Enclosure ProtectionIP67, IP69K (QC version IP67 at connector)
Operating Temperature -25 ... +40 °C
Mechanical Life Expectancy (B10d)2.5 x 10 6 cycles at 100mA load
VibrationIEC68-2-6, 10-55Hz+1Hz Excursion: 0.35mm, 1 octave/min

Characteristic data according to IEC62061 (used as a subsystem)
Safety Integrity Level SIL 3
PFH (1/h)1.0 E-09 (Corresponds to 1% of SIL3)
PFD (Av.)8.7 E-05 (Corresponds to 9% of SIL3)
Proof Test Interval T120a

Characteristic data according to EN ISO13849-1
Performance Level e
CategoryCat 4
MTTFd771a
Diagnostic Coverage DCHigh

Information with regard to UL Standards
Type 1 enclosure. Use Class 2 power supply or equivalent. Maximum temperature 40°C. Use 16-28AWG copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7Nm). Intended for same polarity use. Safety Circuits (11-12 & 21-22) 24V.dc 200mA max. Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit. (Earth bonding terminal inside metal enclosures (if required). Use 16-12AWG conductors)