Z-Range Heavy Duty Safety Rope Pull Switches with Dual Head (GLHD-Z)

The GLHD-Z heavy duty safety rope pull switch has been designed to protect long conveyor lengths. The dual head is capable of protecting up to 250m and shorter rope spans up to 200m can be achieved using a single switch. This makes for a cost-effective solution, as it reduces electrical wiring runs and the total number of switches required.

  • Body Material: Die-Cast Metal; Painted Yellow
  • Ingress Protection: IP67
  • Contacts: 2 OSSD + 1 Auxiliary Output
  • Cable Length (1 Switch): 100m left / 100m right
  • Cable Length (3 Switches): 125m left / 125m right

Part NumberPart DescriptionContact ConfigurationConnection
141300-ZGLHD-Z Z-Range 2 OSSD 1 Auxiliary M12-QC2 OSSD PNP + 1 PNP AUX.250mm Pigtail M12-QC 8-PIN

Technical Data
ApprovalsTUV (on CBZ internal contact block), cULus
TechnologySafety Rope Pull Switch
Housing MaterialPainted Die-Cast Metal
Operating Temperature-20 ... +50 °C
Enclosure ProtectionIP67
Rope SpansUp to 250m
Rope Type4.0mm Outside Dia. Steel inner-PVC sheath
Mounting4 x M5
Torque settingsMounting M5 4.0 Nm Lid T20 Torx M4 1.5 Nm Terminals 1.0 Nm
Tension Force (typical mid setting)130N
Typical Operating Force (Rope pulled)< 125N. < 300mm Deflection
Contact Configuration2 x OSSD PNP + 1 x PNP Auxiliary
Rated Operating Voltage24V DC -15% +10% (Use SELV/PELV)
Power Consumption 0.7W
Outputs Rated Voltage24V DC
Outputs max. / min.Current0.2 A / 1mA
Inputs Rated Voltage / Current24V DC / 2mA
Auxiliary Signalling Output Rated Voltage24V DC
Auxiliary Signalling Output Max. Current0.2 A PNP
Response Time Guard Open60ms max.
Response Time Inputs Off 20ms max.

Characteristic Data according to IEC62061 (used as a sub system)
Safety Integrity Level SIL3
PFH (1/h) 1.0 E-09 (Corresponds to 1% of SIL3)
PFD 8.8 E-05 (Corresponds to 9% of SIL3)
Proof Test Interval T120a

Characteristic Data according to EN ISO13849-1
Performance Levele
Category4
MTTFd771a
Diagnostic Coverage DCHigh

Information with regard to UL Standards
Type 1 Enclosures. Maximum temperature 50ºC. Maximum output 24V DC 100mA. Powered by Class 2 or equivalent.