Panel Mount Trapped Key Control Isolation Switch with Lockout Dust Cover (SS-CS-LT)
The SS-CS-LT is used for isolating an electrical control circuit. Turning the key to the OFF position opens the safety contacts, allowing the key to be removed and transferred to the next stage in the Trapped Key System. The SS-CS-LT comes with a lockout dust cover.
- 316 Grade Stainless Steel Barrel
- 4NC + 2NO Monitoring Contact Block
- Installation via Panel Mounting Holes
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Description | Configuration | Barrel Material | Key Included |
|---|---|---|---|---|
| SS-CS-LT | Control Switch Panel Mount 4NC 2NO | 4 N/C + 2 N/O (When key is Trapped) | 316 Grade Stainless Steel | NO |
| Note |
|---|
| Key sold separately |
| Technical Data | |
|---|---|
| Approvals | cULus |
| Enclosure Material | 316 Grade Stainless Steel |
| Safety Contacts | Utilization Category AC15 A300 3A. Thermal Current (Ith) 5A |
| Overload protection fuse (fuse externally) | 10A. (FF). |
| Auxiliary Contact | 24V.ac/dc 0.5A. maximum |
| Rated Insulation Voltage | 600VAC |
| Rated Impulse Withstand Volt | 2500VAC |
| Operating Temperature | -20 ... +40 °C |
| Mechanical Life (B10d) | 1,000,000 cycles |
| Information with regard to UL Standards |
|---|
| Type 1 enclosure. Maximum temperature 40°C. Use 16-28AWG stranded copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7Nm). Intended for same polarity use. A300 Pilot Duty. 240V. 3A. PF 0.38 or greater, tested for 6,000 cycles endurance |