External Mount Trapped Key Control Isolation Switch with Tongue Interlock (M-TS-CB)
The M-TS-CB is a trapped key gate access lock with an internal contact block. Turning the key unlocks the actuator and opens the safety contacts. The M-TSR-CB has a ‘key trapped’ during normal operation and becomes ‘free’ when the guard is open. The M-TS-CB has a ‘key free’ during normal operation and becomes ‘trapped’ when the guard is open.
- Body Material: Die-Cast Metal
- Ingress Protection: IP67
- Contacts: 2NC + 2NO, 3NC + 1NO or 4NC Monitoring Contact Blocks
- Connection: 3 x M20 or ½” NPT Conduits
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Part Description |
|---|---|
| M-TS-CB-22-M | Single Tongue Interlock 2NC 2NO Contact Block (M20) (Key Free / Door Closed) |
| M-TS-CB-22-N | Single Tongue Interlock 2NC 2NO Contact Block (NPT) (Key Free / Door Closed) |
| M-TS-CB-31-M | Single Tongue Interlock 3NC 1NO Contact Block (M20) (Key Free / Door Closed) |
| M-TS-CB-31-N | Single Tongue Interlock 3NC 1NO Contact Block (NPT) (Key Free / Door Closed) |
| M-TSR-CB-22-M | Single Tongue Interlock 2NC 2NO Contact Block (M20) (Key Free / Door Open) |
| M-TSR-CB-22-N | Single Tongue Interlock 2NC 2NO Contact Block (NPT) (Key Free / Door Open) |
| M-TSR-CB-31-M | Single Tongue Interlock 3NC 1NO Contact Block (M20) (Key Free / Door Open) |
| M-TSR-CB-31-N | Single Tongue Interlock 3NC 1NO Contact Block (NPT) (Key Free / Door Open) |
| Note |
|---|
| Key sold separately |
| Actuator sold separately |
| Please note that for trapped key access locks, either a key or an actuator must be ordered with the product. This is required for manufacturing, as the internal mechanism must be configured to trap one of these parts. For assistance, please contact the IDEM Sales team. |
| Technical Data | |
|---|---|
| Approvals | cULus |
| Enclosure Material | Die-Cast Metal |
| Safety Contact type | IEC 60947-5-1 Double break Type Zb |
| Termination | Clamp up to 2.5 sq. mm conductors |
| Rating | Utilisation Category : AC15 |
| Operational Rating | AC15 A300 240V. 3A /120V 6A. ac |
| Thermal Current (Ith) | 10A |
| Rated Insulation Voltage (Ui) | 500V |
| Withstand Voltage (Uimp) | 2500V |
| Short Circuit Overload Protection | Fuse Externally 10A. (FF) |
| Operating Temperature | -20 ... +60 °C |
| Enclosure Protection | IP67 |
| Holding Force | 3000N. (F1max.) 2307N. (Fzh) |
| Mechanical Life (B10d) | 1,000,000 cycles |