Guard Locking Safety Switch Power to Lock up to 2000N (KLP-P2L)

The KLP-P2L guard locking safety interlock features a slimline plastic body and a holding force of up to 2000N to keep small to medium guard doors closed until hazards have been removed. 24Vdc must be supplied to the solenoid to keep the guard locked.


  • Body Material: High Specification Polyester – Red
  • Head Material: 316 Stainless Steel
  • Holding Force: F1Max 2000N (200Kg)
  • Actuation: Rotating head for 8 entry positions
  • Ingress Protection: IP67
  • Conduit: 1 x M20 or ½” NPT (Quick Connect Available)

 

Product Type Part No. Part Description
KLP-P2L 201021 KLP-P2L M20 24v
KLP-P2L 201021A KLP-P2L M20 24v – std actuator
KLP-P2L 201021F KLP-P2L M20 24v – flat actuator
KLP-P2L 201021HF KLP-P2L M20 24v – HF actuator
KLP-P2L 201021HFH KLP-P2L M20 24v – HFH actuator
KLP-P2L 201022 KLP-P2L ½NPT 24v
KLP-P2L 201022A KLP-P2L ½NPT 24v – std actuator
KLP-P2L 201022F KLP-P2L ½NPT 24v – flat actuator
KLP-P2L 201022HF KLP-P2L ½NPT 24v – HF actuator
KLP-P2L 201022HFH KLP-P2L ½NPT 24v – HFH actuator
KLP-P2L 201023 KLP-P2L QC M23 12way 24v
KLP-P2L 201023A KLP-P2L QC M23 12way 24v – std actuator
KLP-P2L 201023F KLP-P2L QC M23 12way 24v – flat actuator
KLP-P2L 201023HF KLP-P2L QC M23 12way 24v – HF actuator
KLP-P2L 201023HFH KLP-P2L QC M23 12way 24v – HFH actuator
KLP-P2L 201024 KLP-P2L M20 110v
KLP-P2L 201024A KLP-P2L M20 110v – std actuator
KLP-P2L 201024F KLP-P2L M20 110v – flat actuator
KLP-P2L 201024HF KLP-P2L M20 110v – HF actuator
KLP-P2L 201024HFH KLP-P2L M20 110v – HFH actuator
KLP-P2L 201025 KLP-P2L ½ NPT 110v
KLP-P2L 201025A KLP-P2L ½ NPT 110v – std actuator
KLP-P2L 201025F KLP-P2L ½ NPT 110v – flat actuator
KLP-P2L 201025HF KLP-P2L ½ NPT 110v – HF actuator
KLP-P2L 201025HFH KLP-P2L ½ NPT 110v – HFH actuator
KLP-P2L 201026 KLP-P2L QC 110v
KLP-P2L 201026A KLP-P2L QC 110v – std actuator
KLP-P2L 201026F KLP-P2L QC 110v – flat actuator
KLP-P2L 201026HF KLP-P2L QC 110v – HF actuator
KLP-P2L 201026HFH KLP-P2L QC 110v – HFH actuator
KLP-P2L 201027 KLP-P2L M20 230v
KLP-P2L 201027A KLP-P2L M20 230v – std actuator
KLP-P2L 201027F KLP-P2L M20 230v – flat actuator
KLP-P2L 201027HF KLP-P2L M20 230v – HF actuator
KLP-P2L 201027HFH KLP-P2L M20 230v – HFH actuator
KLP-P2L 201028 KLP-P2L ½ NPT 230v
KLP-P2L 201028A KLP-P2L ½ NPT 230v – std actuator
KLP-P2L 201028F KLP-P2L ½ NPT 230v – flat actuator
KLP-P2L 201028HF KLP-P2L ½ NPT 230v – HF actuator
KLP-P2L 201028HFH KLP-P2L ½ NPT 230v – HFH actuator
KLP-P2L 201029 KLP-P2L QC 230v
KLP-P2L 201029A KLP-P2L QC 230v – std actuator
KLP-P2L 201029F KLP-P2L QC 230v – flat actuator
KLP-P2L 201029HF KLP-P2L QC 230v – HF actuator
KLP-P2L 201029HFH KLP-P2L QC 230v – HFH actuator

Technical Data
CertificatescULus
TechnologyPower to Lock
Housing MaterialRed Polyester
Head Material316 Grade Stainless Steel
Solenoid Voltage 24V ac/dc (12W.)
Safety Contacts 11/12 21/22 33/34Utilization Category AC15 A300 3A. Thermal Current (Ith) 5A
Overload protection fuse (fuse externally) 10A. (FF)
Auxiliary Contact 43/44230V.ac/dc 0.5A. Maximum
Rated Insulation Voltage600VAC
Rated Impulse Withstand Volt2500VAC
Travel for Positive Opening10mm
Approach Speed200mm/m. to 1000mm/s
Man. Actuation Frequency2 cycle/sec
Actuator entry minimum radius175mm Standard 100mm Flexible
Enclosure ProtectionIP67
Operating Temperature-25 ... +40 °C
Holding ForceF1Max: 2000N. Fzh: 1538N
VibrationIEC 68-2-6, 10-55Hz+1Hz, Excursion: 0.35mm, 1 octave/min
Conduit EntryM20 or 1/2" NPT
Fixing4 x M5

Safety Classification and Reliability Data
Mechanical Reliability B10d2.5 x 106 operations at 100mA load
ISO 13849-1up to PLe / Cat.4 depending upon system architecture
EN 62061up to SIL3 depending upon system architecture
Safety Data - Annual Usage8 cycles per hour / 24 hours per day / 365 days MTTFd 356 years

Information with regard to UL Standards
Type 1 enclosure. Maximum temperature 40°C. Use 16-28AWG stranded copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7Nm). Intended for same polarity use. A300 Pilot Duty. 240V. 3A. PF 0.38 or greater, tested for 6,000 cycles endurance Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit.