Guardian Line Standard Duty Rope Safety Switch (GLS)
The GLS standard duty safety rope pull switch has been designed to protect medium to long conveyor lengths, where protection is required up to 100m (using 2 switches) or up to 80m (using 1 switch).
- Body Material: Die-Cast Metal; Painted Yellow
- Ingress Protection: IP67
- Contacts: 3-Pole or 4-Pole Contacts
- Cable Length (1 Switch): 80m
- Cable Length (2 Switches): 100m
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part No. | Part Description |
|---|---|
| 142001 | GLS M20 2NC 1NO |
| 142001-FZ | GLS M20 2NC 1NO (-40° version) |
| 142001-QCM12 | GLS QC M12 2NC 1NO |
| 142002 | GLS ½NPT 2NC 1NO |
| 142002-FZ | GLS ½NPT 2NC 1NO (-40° version) |
| 142009 | GLS M20 2NC 1NO E Stop |
| 142009-QCM12 | GLS QC M12 2NC 1NO E Stop |
| 142009FZ | GLS M20 2NC 1NO EStop – Special low temp version |
| 142010 | GLS ½NPT 2NC 1NO E Stop |
| 142010-FZ | GLS ½NPT 2NC 1NO E Stop (-40° version) |
| 142050 | GLS M20 3NC 1NO |
| 142050-FZ | GLS M20 3NC 1NO (-40° version) |
| 142050-QCM23 | GLS QC M23 3NC 1NO |
| 142051 | GLS ½NPT 3NC 1NO |
| 142051-FZ | GLS ½NPT 3NC 1NO (-40° version) |
| 142052 | GLS M20 2NC 2NO |
| 142052-FZ | GLS M20 2NC 2NO (-40° version) |
| 142052-QCM23 | GLS QC M23 2NC 2NO |
| 142053 | GLS ½NPT 2NC 2NO |
| 142053-FZ | GLS ½NPT 2NC 2NO (-40° version) |
| 142054 | GLS M20 4NC |
| 142054-FZ | GLS M20 4NC (-40° version) |
| 142055 | GLS ½NPT 4NC |
| 142055-FZ | GLS ½NPT 4NC (-40° version) |
| 142062 | GLS M20 3NC 1NO E Stop |
| 142062-FZ | GLS M20 3NC 1NO E Stop (-40° version) |
| 142062-QCM23 | GLS QC M23 3NC 1NO E Stop |
| 142063 | GLS ½NPT 3NC 1NO E Stop |
| 142063-FZ | GLS ½NPT 3NC 1NO E Stop (-40° version) |
| 142064 | GLS M20 2NC 2NO E Stop |
| 142064-FZ | GLS M20 2NC 2NO E Stop (-40° version) |
| 142064-QCM23 | GLS QC M23 2NC 2NO E Stop |
| 142065 | GLS ½NPT 2NC 2NO E Stop |
| 142065-FZ | GLS ½NPT 2NC 2NO E Stop (-40° version) |
| 142066 | GLS M20 4NC E Stop |
| 142066-FZ | GLS M20 4NC E Stop (-40° version) |
| 142067 | GLS ½NPT 4NC E Stop |
| 142067-FZ | GLS ½NPT 4NC E Stop (-40° version) |
| Note |
|---|
| FZ models for temperatures down to -40°C. |
| Technical Data | |
|---|---|
| Approvals | TUV, cULus |
| Technology | Safety Rope Pull Switch |
| Housing Material | Yellow Painted Die-Cast Metal |
| Operating Temperature | -25 ... +80 °C (-40C. for -FZ versions) |
| Enclosure Protection | IP67 |
| Rope Spans | Up to 100m |
| Rope Type | 4.0mm Outside Dia. Steel inner-PVC sheath |
| Mounting | 4 x M5 |
| Torque settings | Mounting M5 4.0 Nm Lid T20 Torx M4 1.5 Nm Terminals 1.0 Nm |
| Vibration resistance | 10-500Hz 0.35mm |
| Shock resistance | 15g 11ms |
| Tension Force (typical mid setting) | 130N |
| Typical Operating Force (Rope pulled) | < 125N. < 300mm Deflection |
| Safety Contact type | IEC 60947-5-1 Double break Type Zb |
| Termination | Clamp up to 2.5 sq. mm conductors |
| Rating | Utilisation Category : AC15 |
| Operational Rating | AC15 A300 240V. 3A /120V 6A. ac 24V. 2.5A dc inductive |
| Thermal Current (Ith) | 10A |
| Rated Insulation Voltage (Ui) | 500V |
| Withstand Voltage (Uimp) | 2500V |
| Short Circuit Overload Protection | Fuse Externally 10A. (FF) |
| Safety Classification and Reliability Data | |
|---|---|
| Mechanical Reliability B10d | 1.5 x 10 6 operations at 100mA load |
| ISO 13849-1 | up to Category 4 with Safety Relay |
| ISO 13849-1 | up to PLe depending upon system architecture |
| EN 62061 | up to SIL3 depending upon system architecture |
| Safety Data - Annual Usage | 8 cycles per hour / 24 hours per day / 365 days MTTFd 214 years |
| Information with regard to UL 508 |
|---|
| Type 1 Enclosures. Temperature rating 80C. Use 16 - 12AWG copper conductors, rated 75ºC only. Intended for same polarity use and one polymeric conduit connection. Electrical Rating: A300 240V.ac 3A. (6,000 cycles) 120V. 60A. Making 6A. Breaking PF >0.38 (100,000 cycles) 240V. 10A. carry only. Wire range: 16AWG – 12AWG Copper Torque 7lb/in (0.8Nm) LED powered by LVLC or Class 2 only. Earth bonding terminal inside enclosure if required. |