Z-Range Heavy Duty Safety Rope Pull Switches with Dual Head (GLHD-SS-Z)
The GLHD-SS-Z heavy duty safety rope pull switch has been designed to protect long conveyor lengths. The dual head is capable of protecting up to 250m and shorter rope spans up to 200m can be achieved using a single switch. This makes for a cost-effective solution, as it reduces electrical wiring runs and the total number of switches required.
- Body Material: Stainless Steel 316
- Ingress Protection: IP69K (IP67 at the connector)
- Contacts: 2 OSSD + 1 Auxiliary Output
- Cable Length (1 Switch): 100m left / 100m right
- Cable Length (3 Switches): 125m left / 125m right
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Part Description | Contact Configuration | Connection |
|---|---|---|---|
| 145300-Z | GLHD-SS-Z Z-Range 2 OSSD 1 Auxiliary M12-QC | 2 OSSD PNP + 1 PNP AUX. | 250mm Pigtail M12-QC 8-PIN |
| Technical Data | |
|---|---|
| Approvals | TUV (on CBZ internal contact block), cULus |
| Technology | Safety Rope Pull Switch |
| Housing Material | 316 Grade Stainless Steel |
| Operating Temperature | -20 ... +50 °C |
| Enclosure Protection | IP67, IP69K (The M12 Quick Connect is rated to IP67) |
| Rope Spans | Up to 250m |
| Rope Type | 4.0mm Outside Dia. Steel inner-PVC sheath |
| Mounting | 4 x M5 |
| Torque settings | Mounting M5 4.0 Nm Lid T20 Torx M4 1.5 Nm Terminals 1.0 Nm |
| Tension Force (typical mid setting) | 130N |
| Typical Operating Force (Rope pulled) | < 125N. < 300mm Deflection |
| Contact Configuration | 2 x OSSD PNP + 1 x PNP Auxiliary |
| Rated Operating Voltage | 24V DC -15% +10% (Use SELV/PELV) |
| Power Consumption | 0.7W |
| Outputs Rated Voltage | 24V DC |
| Outputs max. / min.Current | 0.2 A / 1mA |
| Inputs Rated Voltage / Current | 24V DC / 2mA |
| Auxiliary Signalling Output Rated Voltage | 24V DC |
| Auxiliary Signalling Output Max. Current | 0.2 A PNP |
| Response Time Guard Open | 60ms max. |
| Response Time Inputs Off | 20ms max. |
| Characteristic Data according to IEC62061 (used as a sub system) | |
|---|---|
| Safety Integrity Level | SIL3 |
| PFH (1/h) | 1.0 E-09 (Corresponds to 1% of SIL3) |
| PFD | 8.8 E-05 (Corresponds to 9% of SIL3) |
| Proof Test Interval T1 | 20a |
| Characteristic Data according to EN ISO13849-1 | |
|---|---|
| Performance Level | e |
| Category | 4 |
| MTTFd | 771a |
| Diagnostic Coverage DC | High |
| Information with regard to UL Standards |
|---|
| Type 1 Enclosures. Maximum temperature 50ºC. Maximum output 24V DC 100mA. Powered by Class 2 or equivalent. |