Stainless Steel Safety Limit Switch with Adjustable Roller Lever (HLM-SS-ARL)
The adjustable roller lever limit switches from IDEM Safety are designed to be mounted for position sensing of moving applications e.g., guard doors, conveyors, machine beds, elevators etc. The internal contact block is positively operated to comply with IEC 60947-5-1.
- Material: 316 Stainless Steel with Mirror Polished Lid
- Actuation: Adjustable Roller Lever
- Ingress Protection: IP69K
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part No. | Part Description |
|---|---|
| 175301 | HLM-SS Adj Roller Lever M20 2NC 2NO |
| 175301-GC | HLM-SS Adj Roller Lever M20 2NC 2NO |
| 175302 | HLM-SS Adj Roller Lever ½NPT 2NC 2NO |
| 175303 | HLM-SS Adj Roller Lever QC-M23 2NC 2NO |
| 175304 | HLM-SS Adj Roller Lever M20 3NC 1NO |
| 175305 | HLM-SS Adj Roller Lever ½NPT 3NC 1NO |
| 175306 | HLM-SS Adj Roller Lever QC-M23 3NC 1NO |
| 175307 | HLM-SS Adj Roller Lever M20 4NC |
| 175307-GC | HLM-SS Adj Roller Lever M20 4NC – GOLD CONTACTS |
| 175308 | HLM-SS Adj Roller Lever ½NPT 4NC |
| 175309 | HLM-SS Adj Roller Lever QC-M23 4NC |
| 175310 | HLM-SS Adj Roller Lever M20 1NC 1NO Snap |
| 175311 | HLM-SS Adj Roller Lever ½NPT 1NC 1NO Snap |
| 175312 | HLM-SS Adj Roller Lever QC-M23 1NC 1NO Snap |
| Note |
|---|
| Gold plated contacts are available for circuits with low power (5V 5mA). |
| Technical Data | |
|---|---|
| Approvals | cULus |
| Material | 316 Grade Stainless Steel |
| Enclosure Protection | IP67, IP69K (NEMA 6) |
| Operating Temperature | -25 ... +80 °C |
| Typical operating parameters | 0.4Nm Torque 15-30 degrees contact changeover |
| Vibration | IEC 68-2-6, 10-55Hz 0.35mm |
| Conductor size | 1.5 sq.mm |
| Fixing | M5 Bolts |
| Positive Opening Operation | NC Contacts |
| Utilization Category | AC15 A300 240V. 3A |
| Min Current | 5V, 5mA, DC |
| Thermal Current (Ith) | 10A |
| Rated Impulse Withstand Volt | 2500VAC |
| Information with regard to UL Standards |
|---|
| Type 1 Enclosures. Use 16 - 12AWG copper conductors, rated 75ºC minimum. Intended for same polarity use. Electrical Rating: A300 240V.ac 3A. (6,000 cycles) 240V. 10A. carry only. Wire range: 16AWG – 12AWG Copper Torque 7lb/in (0.8Nm) Earth bonding terminal inside enclosure if required. |