KLTM Guard Locking Safety Switch

The KLTM guard locking safety interlock features a industry standard metal body and a holding force of up to 3000N to keep small to large guard doors closed until hazards have been removed.


  • Manufactured from die-cast metal
  • Head manufactured from 316 stainless steel
  • Holding Force up to F1Max 3000N (300Kg)
  • Rotating head for up to 4 entry positions
  • Ingress Protection up to IP67
  • 3 x M20 or ½” NPT (Quick Connect Available)
Part Number Part Description Voltage Connection Type Actuator
450001 KLTM (Mechanical Only) M20 24v 24V M20 No Actuator
450001A KLTM (Mechanical Only) M20 24v – Std Actuator 24V M20 A – Standard Actuator
450001F KLTM (Mechanical Only) M20 24v – Flat Actuator 24V M20 F – Flat Actuator
450001HF KLTM (Mechanical Only) M20 24v – HF Actuator 24V M20 HF – Metal Flexible Actuator
450001HFH KLTM (Mechanical Only) M20 24v – HFH Actuator 24V M20 HFH – Stainless Steel Flexible Actuator
450002 KLTM (Mechanical Only) ½”NPT 24v 24V ½NPT No Actuator
450002A KLTM (Mechanical Only) ½”NPT 24v – Std Actuator 24V ½NPT A – Standard Actuator
450002F KLTM (Mechanical Only) ½”NPT 24v – Flat Actuator 24V ½NPT F – Flat Actuator
450002HF KLTM (Mechanical Only) ½”NPT 24v – HF Actuator 24V ½NPT HF – Metal Flexible Actuator
450002HFH KLTM (Mechanical Only) ½”NPT 24v – HFH Actuator 24V ½NPT HFH – Stainless Steel Flexible Actuator
450004 KLTM (Mechanical Only) M20 110v 110V M20 No Actuator
450004A KLTM (Mechanical Only) M20 110v – Std Actuator 110V M20 A – Standard Actuator
450004F KLTM (Mechanical Only) M20 110v – Flat Actuator 110V M20 F – Flat Actuator
450004HF KLTM (Mechanical Only) M20 110v – HF Actuator 110V M20 HF – Metal Flexible Actuator
450004HFH KLTM (Mechanical Only) M20 110v – HFH Actuator 110V M20 HFH – Stainless Steel Flexible Actuator
450005 KLTM (Mechanical Only) ½”NPT 110v 110V ½NPT No Actuator
450005A KLTM (Mechanical Only) ½”NPT 110v – Std Actuator 110V ½NPT A – Standard Actuator
450005F KLTM (Mechanical Only) ½”NPT 110v – Flat Actuator 110V ½NPT F – Flat Actuator
450005HF KLTM (Mechanical Only) ½”NPT 110v – HF Actuator 110V ½NPT HF – Metal Flexible Actuator
450005HFH KLTM (Mechanical Only) ½”NPT 110v – HFH Actuator 110V ½NPT HFH – Stainless Steel Flexible Actuator
450007 KLTM (Mechanical Only) M20 230v 230V M20 No Actuator
450007A KLTM (Mechanical Only) M20 230v – Std Actuator 230V M20 A – Standard Actuator
450007F KLTM (Mechanical Only) M20 230v – Flat Actuator 230V M20 F – Flat Actuator
450007HF KLTM (Mechanical Only) M20 230v – HF Actuator 230V M20 HF – Metal Flexible Actuator
450007HFH KLTM (Mechanical Only) M20 230v – HFH Actuator 230V M20 HFH – Stainless Steel Flexible Actuator
450008 KLTM (Mechanical Only) ½”NPT 230v 230V ½NPT No Actuator
450008A KLTM (Mechanical Only) ½”NPT 230v – Std Actuator 230V ½NPT A – Standard Actuator
450008F KLTM (Mechanical Only) ½”NPT 230v – Flat Actuator 230V ½NPT F – Flat Actuator
450008HF KLTM (Mechanical Only) ½”NPT 230v – HF Actuator 230V ½NPT HF – Metal Flexible Actuator
450008HFH KLTM (Mechanical Only) ½”NPT 230v – HFH Actuator 230V ½NPT HFH – Stainless Steel Flexible Actuator

Note
Internal selector switch to be used as either power feed to LED 2 or as a voltage free auxiliary circuit to indicate the lock status.

Technical Data
CertificatescULus
TechnologyPower to Unlock
Material Red Painted Die-Cast with Stainless Steel Head
Solenoid Voltage (by part number) 24V ac/dc or 110V. ac or 230V. ac +/- 10% (12W.)
LED 2 Supply Voltage 24V dc +/- 10%
Safety Contacts 11/12 21/22Utilization Category AC15 A300 3A. Thermal Current (Ith) 5A
Overload protection fuse (fuse externally) 10A. (FF).
Auxiliary Contact 33/34 (selectable with LED2)24V.ac/dc 0.5A. maximum
Auxiliary Contact 43/44230V.ac/dc 0.5A. maximum
Rated Insulation Voltage600VAC
Rated Impulse Withstand Volt2500VAC
Travel for Positive Opening10mm
Approach Speed200mm/m. to 1000mm/s
Man. Actuation Frequency2 cycle/sec
Actuator entry minimum radius175mm Standard 100mm Flexible
Enclosure ProtectionIP67
Operating Temperature-25 ... +40 °C
Holding ForceF1Max: 3000N. Fzh: 2307N
VibrationIEC 68-2-6, 10-55Hz+1Hz, Excursion: 0.35mm, 1 octave/min
Conduit EntryM20 or 1/2" NPT
Fixing4 x M5

Information with regard to UL Standards
EnclosureType 1
Maximum temperature+40 °C
Terminal Torquee 6 lb ins. (0.7Nm)
Use 16-28AWG stranded copper conductors (rated 90°C)
Intended for same polarity use. A300 Pilot Duty. 240V. 3A
PF 0.38 or greater, tested for 6,000 cycles endurance
Use one polymeric conduit connection
Not suitable for connection to rigid metal conduit
(Earth bonding terminal inside enclosure if required)