KLTM-RFID QC-M23 Guard Locking Safety Switch with RFID and M23 Quick Connect

The KLTM-RFID QC-M23 guard locking safety interlock with integrated RFID is housed in a heavy-duty die-cast enclosure and provides a holding force of up to 3000 N across two actuator entry points. Designed for medium to large guard doors, it helps keep guards securely closed until hazardous motion has stopped or the hazard has been removed. The integrated M23 connector reduces installation time, minimizes wiring errors, and makes maintenance or replacement faster and more reliable.

The uniquely coded RFID actuator provides high-level coding in accordance with ISO 14119, delivering a high level of anti-tamper protection and helping to prevent unauthorised operation.


  • Manufactured from Heavy-Duty Die-Cast Metal
  • Head Manufactured from 316 Stainless Steel for Long-Term Durability
  • Holding Force up to 3000 N
  • Ingress Protection up to IP67
  • RFID is Uniquely Coded (Can be Retaught if Lost or Damaged)
  • 2 NC 1 NO Guard Position Monitoring / 2 NC 1 NO Lock Monitoring
Part No. Part Description
450203 KLTM-RFID (Uniquely coded) QC M23 24v (Front/End Lower)
450303 KLTM-RFID (Uniquely coded) QC M23 24v (Rear/Front Upper)

Technical Data
ApprovalsTUV, cULus
Classification and Coding Level according to EN ISO 14119Type 4, High
TechnologyRFID, Power to Unlock
Housing MaterialPainted Die-Cast Metal
Head Material316 Grade Stainless Steel
Supply Voltage24Vdc (+/- 10%)
Power ConsumptionR+ 1.2W (50mA Max.) / S+ 12W (500mA Max.)
Safety Circuits24Vdc 200mA max. switching
Auxiliary Circuits (34 & 44)24Vdc 200mA max. Output feed
Rated Insulation Voltage500VAC
Rated Impulse withstand1000VAC
Holding ForceF1Max 3000N Fzh 2307N
Assured locking distance5mm
Sao (RFID)10mm
Sar (RFID) 20mm
Max operating frequency1Hz
Actuator entry minimum radius175mm
Enclosure ProtectionIP67
Operating Temperature -25 ... +40 °C
Mechanical Life Expectancy (B10d)2.5 x 106 cycles at 100mA load
VibrationIEC68-2-6, 10-55Hz+1Hz Excursion: 0.35mm, 1 octave/min

Characteristic data according to IEC62021 (used as a subsystem)
Safety Integrity LevelSIL 3
PFH (1/h)4.77E-10 (Corresponds to 4.8% of SIL3)
PFD4.18E-05 (Corresponds to 4.2% of SIL3)
Proof Test Interval T120a

Characteristic data according to EN ISO13849-1
Performance Levele (If both channels are used in conjunction with a SIL 3 / PL e control Device).
Diagnostic Coverage DC99% (High) (If both channels are used in conjunction with a SIL 3 / PL e control Device).
CategoryCat 4.
MTTFd1100a

Information with regard to UL standards
Type 1 enclosure. Maximum temperature 40°C. Use 16-28AWG copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7Nm). Intended for same polarity use. Safety Circuits (11-31 & 21-41) A300 Pilot Duty. 240V. 3A. (PF 0.38 or greater tested for 6,000 cycles endurance). Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit. (Earth bonding terminal inside enclosure if required – use 16-12AWG conductors)