KLTM QC-M23 Guard Locking Safety Switch with M23 Quick Connect
The KLTM guard locking safety interlock features a industry standard metal body and a holding force of up to 3000N to keep small to large guard doors closed until hazards have been removed. The integrated M23 connector reduces installation time, minimizes wiring errors, and makes maintenance or replacement faster and more reliable.
- Manufactured from die-cast metal
- Head manufactured from 316 Stainless Steel
- Holding Force up to F1Max 3000N (300Kg)
- Rotating head for up to 4 entry positions
- Ingress Protection up to IP67
- Quick connect M23 12-pin male
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Part Description | Voltage | Connection Type | Actuator |
|---|---|---|---|---|
| 450003 | KLTM (Mechanical Only) QC M23 24v | 24V | QC M23 | No Actuator |
| 450003A | KLTM (Mechanical Only) QC M23 24v – Std Actuator | 24V | QC M23 | A – Standard Actuator |
| 450003F | KLTM (Mechanical Only) QC M23 24v – Flat Actuator | 24V | QC M23 | F – Flat Actuator |
| 450003HF | KLTM (Mechanical Only) QC M23 24v – HF Actuator | 24V | QC M23 | HF – Metal Flexible Actuator |
| 450003HFH | KLTM (Mechanical Only) QC M23 24v – HFH Actuator | 24V | QC M23 | HFH – Stainless Steel Flexible Actuator |
| 450006 | KLTM (Mechanical Only) QC M23 110v | 110V | QC M23 | No Actuator |
| 450006A | KLTM (Mechanical Only) QC M23 110v – Std Actuator | 110V | QC M23 | A – Standard Actuator |
| 450006F | KLTM (Mechanical Only) QC M23 110v – Flat Actuator | 110V | QC M23 | F – Flat Actuator |
| 450006HF | KLTM (Mechanical Only) QC M23 110v – HF Actuator | 110V | QC M23 | HF – Metal Flexible Actuator |
| 450006HFH | KLTM (Mechanical Only) QC M23 110v – HFH Actuator | 110V | QC M23 | HFH – Stainless Steel Flexible Actuator |
| 450009 | KLTM (Mechanical Only) QC M23 230v | 230V | QC M23 | No Actuator |
| 450009A | KLTM (Mechanical Only) QC M23 230v – Std Actuator | 230V | QC M23 | A – Standard Actuator |
| 450009F | KLTM (Mechanical Only) QC M23 230v – Flat Actuator | 230V | QC M23 | F – Flat Actuator |
| 450009HF | KLTM (Mechanical Only) QC M23 230v – HF Actuator | 230V | QC M23 | HF – Metal Flexible Actuator |
| 450009HFH | KLTM (Mechanical Only) QC M23 230v – HFH Actuator | 230V | QC M23 | HFH – Stainless Steel Flexible Actuator |
| Note |
|---|
| Internal selector switch to be used as either power feed to LED 2 or as a voltage free auxiliary circuit to indicate the lock status. |
| Technical Data | |
|---|---|
| Certificates | cULus |
| Technology | Power to Unlock |
| Material | Red Painted Die-Cast with Stainless Steel Head |
| Solenoid Voltage (by part number) | 24V ac/dc or 110V. ac or 230V. ac +/- 10% (12W.) |
| LED 2 Supply Voltage | 24V dc +/- 10% |
| Safety Contacts 11/12 21/22 | Utilization Category AC15 A300 3A. Thermal Current (Ith) 5A |
| Overload protection fuse (fuse externally) | 10A. (FF). |
| Auxiliary Contact 33/34 (selectable with LED2) | 24V.ac/dc 0.5A. maximum |
| Auxiliary Contact 43/44 | 230V.ac/dc 0.5A. maximum |
| Rated Insulation Voltage | 600VAC |
| Rated Impulse Withstand Volt | 2500VAC |
| Travel for Positive Opening | 10mm |
| Approach Speed | 200mm/m. to 1000mm/s |
| Man. Actuation Frequency | 2 cycle/sec |
| Actuator entry minimum radius | 175mm Standard 100mm Flexible |
| Enclosure Protection | IP67 |
| Operating Temperature | -25 ... +40 °C |
| Holding Force | F1Max: 3000N. Fzh: 2307N |
| Vibration | IEC 68-2-6, 10-55Hz+1Hz, Excursion: 0.35mm, 1 octave/min |
| Connection | Quick Connect M23 12-PIN Male |
| Fixing | 4 x M5 |
| Information with regard to UL Standards | |
|---|---|
| Enclosure | Type 1 |
| Maximum temperature | +40 °C |
| Terminal Torque | e 6 lb ins. (0.7Nm) |
| Use 16-28AWG stranded copper conductors (rated 90°C) | |
| Intended for same polarity use. A300 Pilot Duty. 240V. 3A | |
| PF 0.38 or greater, tested for 6,000 cycles endurance | |
| Use one polymeric conduit connection | |
| Not suitable for connection to rigid metal conduit | |
| (Earth bonding terminal inside enclosure if required) |