KLTM-P2L QC-M23 Guard Locking Safety Switch with Power to Lock and M23 Quick Connect

The KLTM-P2L guard locking safety interlock features a low profile body and with industry standard 73mm fixing centre, to enable easy retrofitting to new or existing guards. The robust design allows for a holding force of up to 3000N to keep medium to large guard doors closed until the hazard/s have been removed. 24Vdc must be supplied to the solenoid to keep the guard locked.


  • Manufactured from die-cast metal
  • Head manufactured from Mirror Polished, 316 Stainless Steel
  • Holding Force up to F1Max 3000N (300Kg)
  • Rotating head for up to 4 entry positions
  • Ingress Protection up to IP67
  • 3 x M20 or ½” NPT (Quick Connect Available)

 

Part Number Part Description Voltage Connection Type Actuator
450023 KLTM-P2L (Mechanical Only) QC M23 24v 24V QC M23 No Actuator
450023A KLTM-P2L (Mechanical Only) QC M23 24v – Std Actuator 24V QC M23 A – Standard Actuator
450023F KLTM-P2L (Mechanical Only) QC M23 24v – Flat Actuator 24V QC M23 F – Flat Actuator
450023HF KLTM-P2L (Mechanical Only) QC M23 24v – HF Actuator 24V QC M23 HF – Metal Flexible Actuator
450023HFH KLTM-P2L (Mechanical Only) QC M23 24v – HFH Actuator 24V QC M23 HFH – Stainless Steel Flexible Actuator

Technical Data
CertificatescULus
TechnologyPower to Lock
Housing MaterialPainted Die-Cast Metal
Head Material316 Grade Stainless Steel
Solenoid Voltage24V ac/dc (12W.)
Safety Contacts 11/12 21/22 33/34 Utilization Category AC15 A300 3A. Thermal Current (Ith) 5A
Overload protection fuse (fuse externally)10A. (FF)
Auxiliary Contact 43/44230V.ac/dc 0.5A. Maximum
Rated Insulation Voltage600VAC
Rated Impulse Withstand Volt2500VAC
Travel for Positive Opening 10mm
Approach Speed200mm/m. to 1000mm/s
Man. Actuation Frequency2 cycle/sec
Actuator entry minimum radius175mm Standard 100mm Flexible
Enclosure ProtectionIP67
Operating Temperature-25 ... +40 °C
Holding ForceF1Max: 3000N. Fzh: 2307N
VibrationIEC 68-2-6, 10-55Hz+1Hz, Excursion: 0.35mm, 1 octave/min
Conduit EntryM20 or 1/2" NPT
Fixing4 x M5

Safety Classification and Reliability Data
Mechanical Reliability B10d 2.5 x 106 operations at 100mA load
ISO 13849-1 up to PLe / Cat.4 depending upon system architecture
EN 62061up to SIL3 depending upon system architecture
Safety Data - Annual Usage8 cycles per hour / 24 hours per day / 365 days
PFHd3.44 x 10-8
Proof Test Interval (Life)35 years
MTTFd356 years

Information with regard to UL Standards
Type 1 enclosure. Maximum temperature 40°C. Use 16-28AWG stranded copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7Nm). Intended for same polarity use. A300 Pilot Duty. 240V. 3A. PF 0.38 or greater, tested for 6,000 cycles endurance Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit.