KLTM-P2L QC-M23 Guard Locking Safety Switch with Power to Lock and M23 Quick Connect
The KLTM-P2L guard locking safety interlock features a low profile body and with industry standard 73mm fixing centre, to enable easy retrofitting to new or existing guards. The robust design allows for a holding force of up to 3000N to keep medium to large guard doors closed until the hazard/s have been removed. 24Vdc must be supplied to the solenoid to keep the guard locked.
- Manufactured from die-cast metal
- Head manufactured from Mirror Polished, 316 Stainless Steel
- Holding Force up to F1Max 3000N (300Kg)
- Rotating head for up to 4 entry positions
- Ingress Protection up to IP67
- 3 x M20 or ½” NPT (Quick Connect Available)
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Part Description | Voltage | Connection Type | Actuator |
|---|---|---|---|---|
| 450023 | KLTM-P2L (Mechanical Only) QC M23 24v | 24V | QC M23 | No Actuator |
| 450023A | KLTM-P2L (Mechanical Only) QC M23 24v – Std Actuator | 24V | QC M23 | A – Standard Actuator |
| 450023F | KLTM-P2L (Mechanical Only) QC M23 24v – Flat Actuator | 24V | QC M23 | F – Flat Actuator |
| 450023HF | KLTM-P2L (Mechanical Only) QC M23 24v – HF Actuator | 24V | QC M23 | HF – Metal Flexible Actuator |
| 450023HFH | KLTM-P2L (Mechanical Only) QC M23 24v – HFH Actuator | 24V | QC M23 | HFH – Stainless Steel Flexible Actuator |
| Technical Data | |
|---|---|
| Certificates | cULus |
| Technology | Power to Lock |
| Housing Material | Painted Die-Cast Metal |
| Head Material | 316 Grade Stainless Steel |
| Solenoid Voltage | 24V ac/dc (12W.) |
| Safety Contacts 11/12 21/22 33/34 | Utilization Category AC15 A300 3A. Thermal Current (Ith) 5A |
| Overload protection fuse (fuse externally) | 10A. (FF) |
| Auxiliary Contact 43/44 | 230V.ac/dc 0.5A. Maximum |
| Rated Insulation Voltage | 600VAC |
| Rated Impulse Withstand Volt | 2500VAC |
| Travel for Positive Opening | 10mm |
| Approach Speed | 200mm/m. to 1000mm/s |
| Man. Actuation Frequency | 2 cycle/sec |
| Actuator entry minimum radius | 175mm Standard 100mm Flexible |
| Enclosure Protection | IP67 |
| Operating Temperature | -25 ... +40 °C |
| Holding Force | F1Max: 3000N. Fzh: 2307N |
| Vibration | IEC 68-2-6, 10-55Hz+1Hz, Excursion: 0.35mm, 1 octave/min |
| Conduit Entry | M20 or 1/2" NPT |
| Fixing | 4 x M5 |
| Safety Classification and Reliability Data | |
|---|---|
| Mechanical Reliability B10d | 2.5 x 106 operations at 100mA load |
| ISO 13849-1 | up to PLe / Cat.4 depending upon system architecture |
| EN 62061 | up to SIL3 depending upon system architecture |
| Safety Data - Annual Usage | 8 cycles per hour / 24 hours per day / 365 days |
| PFHd | 3.44 x 10-8 |
| Proof Test Interval (Life) | 35 years |
| MTTFd | 356 years |
| Information with regard to UL Standards |
|---|
| Type 1 enclosure. Maximum temperature 40°C. Use 16-28AWG stranded copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7Nm). Intended for same polarity use. A300 Pilot Duty. 240V. 3A. PF 0.38 or greater, tested for 6,000 cycles endurance Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit. |