KLT-SS-RFID Guard Locking Safety Switch with RFID and M23 Quick Connect
The KLT-SS-RFID is a heavy-duty Type 4 guard-locking safety switch with integrated RFID technology. Its robust design provides a holding force of up to 3000 N, helping keep medium to large guard doors securely closed until hazards have been removed.
The integrated M23 connector reduces installation time, helps prevent wiring errors, and makes maintenance or replacement faster, simpler, and more reliable.
The KLT-SS-RFID is suitable for applications requiring strict washdown procedures, including high-temperature, high-pressure washing and exposure to corrosive cleaning chemicals.
- Manufactured from Mirror Polished 316 Grade Stainless Steel
- Ingress protection up to IP69K
- High coded RFID (can be retaught if lost or damaged)
- 4 N/C Safety Outputs and 2 N/O Auxiliary Outputs
- Holding Force up to F1Max 3000N (300Kg)
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Part Description |
|---|---|
| 451203 | KLT-SS-RFID (Uniquely Coded) QC M23 24v (Front/End Lower) |
| 451303 | KLT-SS-RFID (Uniquely Coded) QC M23 24v (Rear/Front Upper) |
| Technical Data | |
|---|---|
| Approvals | TUV, cULus |
| Classification and Coding Level according to EN ISO 14119 | Type 4, High |
| Technology | RFID, Power to Unlock |
| Housing Material | 316 Grade Stainless Steel |
| Supply Voltage | 24Vdc (+/- 10%) |
| Power Consumption | R+ 1.2W (50mA Max.) / S+ 12W (500mA Max.) |
| Safety Circuits | 24Vdc 200mA max. switching |
| Auxiliary Circuits (34 & 44) | 24Vdc 200mA max. Output feed |
| Rated Insulation Voltage | 500VAC |
| Rated Impulse withstand | 1000VAC |
| Holding Force | F1Max 3000N Fzh 2307N |
| Assured locking distance | 5mm |
| Sao (RFID) | 10mm |
| Sar (RFID) | 20mm |
| Max operating frequency | 1Hz |
| Actuator entry minimum radius | 175mm |
| Enclosure Protection | IP69K |
| Operating Temperature | -25 ... +40 °C |
| Mechanical Life Expectancy (B10d) | 2.5 x 106 cycles at 100mA load |
| Vibration | IEC68-2-6, 10-55Hz+1Hz Excursion: 0.35mm, 1 octave/min |
| Characteristic data according to IEC62021 (used as a subsystem) | |
|---|---|
| Safety Integrity Level | SIL 3 |
| PFH (1/h) | 4.77E-10 (Corresponds to 4.8% of SIL3 ) |
| PFD | 4.18E-05 (Corresponds to 4.2% of SIL3) |
| Proof Test Interval T1 | 20a |
| Characteristic data according to EN ISO13849-1 | |
|---|---|
| Performance Level | e (If both channels are used in conjunction with a SIL 3 / PL e control Device). |
| Diagnostic Coverage DC | 99% (High) (If both channels are used in conjunction with a SIL 3 / PL e control Device). |
| Category | Cat 4. |
| MTTFd | 1100a |
| Information with regard to UL standards |
|---|
| Type 1 enclosure. Maximum temperature 40°C. Use 16-28AWG copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7Nm). Intended for same polarity use. Safety Circuits (11-31 & 21-41) A300 Pilot Duty. 240V. 3A. (PF 0.38 or greater tested for 6,000 cycles endurance). Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit. (Earth bonding terminal inside enclosure if required – use 16-12AWG conductors) |