KLP-P2L Guard Locking Safety Switch with Power-to-Lock

The KLP-P2L guard locking safety interlock features a slimline plastic body and a holding force of up to 2000N to keep small to medium guard doors closed until hazards have been removed. 24Vdc must be supplied to the solenoid to keep the guard locked.


  • Body manufactured from high specification polyester – Red
  • Head manufactured from 316 Stainless Steel
  • Holding Force up to F1Max 2000N (200Kg)
  • Operates as a power-to-lock device
  • Rotating head for up to 8 entry positions
  • Ingress Protection up to IP67
  • Connectivity via 1 x M20 or ½” NPT

 

Part Number Part Description Voltage Conduit Type Actuator
201021 KLP-P2L M20 24v 24V M20 No Actuator
201021A KLP-P2L M20 24v – std actuator 24V M20 A – Standard Actuator
201021F KLP-P2L M20 24v – flat actuator 24V M20 F – Flat Actuator
201021HF KLP-P2L M20 24v – HF actuator 24V M20 HF – Metal Flexible Actuator
201021HFH KLP-P2L M20 24v – HFH actuator 24V M20 HFH – Stainless Steel Flexible Actuator
201022 KLP-P2L ½NPT 24v 24V ½NPT No Actuator
201022A KLP-P2L ½NPT 24v – std actuator 24V ½NPT A – Standard Actuator
201022F KLP-P2L ½NPT 24v – flat actuator 24V ½NPT F – Flat Actuator
201022HF KLP-P2L ½NPT 24v – HF actuator 24V ½NPT HF – Metal Flexible Actuator
201022HFH KLP-P2L ½NPT 24v – HFH actuator 24V ½NPT HFH – Stainless Steel Flexible Actuator
201024 KLP-P2L M20 110v 110V M20 No Actuator
201024A KLP-P2L M20 110v – std actuator 110V M20 A – Standard Actuator
201024F KLP-P2L M20 110v – flat actuator 110V M20 F – Flat Actuator
201024HF KLP-P2L M20 110v – HF actuator 110V M20 HF – Metal Flexible Actuator
201024HFH KLP-P2L M20 110v – HFH actuator 110V M20 HFH – Stainless Steel Flexible Actuator
201025 KLP-P2L ½ NPT 110v 110V ½NPT No Actuator
201025A KLP-P2L ½ NPT 110v – std actuator 110V ½NPT A – Standard Actuator
201025F KLP-P2L ½ NPT 110v – flat actuator 110V ½NPT F – Flat Actuator
201025HF KLP-P2L ½ NPT 110v – HF actuator 110V ½NPT HF – Metal Flexible Actuator
201025HFH KLP-P2L ½ NPT 110v – HFH actuator 110V ½NPT HFH – Stainless Steel Flexible Actuator
201027 KLP-P2L M20 230v 230V M20 No Actuator
201027A KLP-P2L M20 230v – std actuator 230V M20 A – Standard Actuator
201027F KLP-P2L M20 230v – flat actuator 230V M20 F – Flat Actuator
201027HF KLP-P2L M20 230v – HF actuator 230V M20 HF – Metal Flexible Actuator
201027HFH KLP-P2L M20 230v – HFH actuator 230V M20 HFH – Stainless Steel Flexible Actuator
201028 KLP-P2L ½ NPT 230v 230V ½NPT No Actuator
201028A KLP-P2L ½ NPT 230v – std actuator 230V ½NPT A – Standard Actuator
201028F KLP-P2L ½ NPT 230v – flat actuator 230V ½NPT F – Flat Actuator
201028HF KLP-P2L ½ NPT 230v – HF actuator 230V ½NPT HF – Metal Flexible Actuator
201028HFH KLP-P2L ½ NPT 230v – HFH actuator 230V ½NPT HFH – Stainless Steel Flexible Actuator

Technical Data
CertificatescULus
TechnologyPower to Lock
Housing MaterialRed Polyester
Head Material316 Grade Stainless Steel
Solenoid Voltage 24V ac/dc (12W.)
Safety Contacts 11/12 21/22 33/34Utilization Category AC15 A300 3A. Thermal Current (Ith) 5A
Overload protection fuse (fuse externally) 10A. (FF)
Auxiliary Contact 43/44230V.ac/dc 0.5A. Maximum
Rated Insulation Voltage600VAC
Rated Impulse Withstand Volt2500VAC
Travel for Positive Opening10mm
Approach Speed200mm/m. to 1000mm/s
Man. Actuation Frequency2 cycle/sec
Actuator entry minimum radius175mm Standard 100mm Flexible
Enclosure ProtectionIP67
Operating Temperature-25 ... +40 °C
Holding ForceF1Max: 2000N. Fzh: 1538N
VibrationIEC 68-2-6, 10-55Hz+1Hz, Excursion: 0.35mm, 1 octave/min
Conduit EntryM20 or 1/2" NPT
Fixing4 x M5

Safety Classification and Reliability Data
Mechanical Reliability B10d2.5 x 106 operations at 100mA load
ISO 13849-1up to PLe / Cat.4 depending upon system architecture
EN 62061up to SIL3 depending upon system architecture
Safety Data - Annual Usage8 cycles per hour / 24 hours per day / 365 days MTTFd 356 years

Information with regard to UL Standards
Type 1 enclosure. Maximum temperature 40°C. Use 16-28AWG stranded copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7Nm). Intended for same polarity use. A300 Pilot Duty. 240V. 3A. PF 0.38 or greater, tested for 6,000 cycles endurance Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit.