KLM-Z-SKR-RR QC-M12 Guard Locking Safety Switch with RFID, OSSD, Personnel Key, Rear Release and M12 Quick Connect

The KLM-Z-SKR-RR QC-M12 guard locking RFID safety interlock with OSSD outputs features a slimline metal body profile, designed for 50 mm frames to enable easy retrofitting to new or existing guards. Its robust construction provides a holding force of up to 3000 N, helping to keep medium to large guard doors securely closed until hazardous motion has stopped or the hazard has been removed.

The coded release key, also known as the Personnel Key, can be taken inside the hazardous area, allowing the user to operate safely and without fear of inadvertent start-up. The KLM-Z-SKR-RR also includes a non-latching rear release mechanism, enabling the guard lock to be released quickly from inside the guarded area in an emergency.


  • Body manufactured from Die-Cast Metal Painted Red
  • Head manufactured from 316 Stainless Steel
  • Ingress protection up to IP67
  • Non-latching rear release mechanism
  • High Coded RFID to ISO 14119
  • 2 OSSD PNP Outputs and 2 Auxiliary Outputs (Door Position / Lock Status)
  • Holding force up to F1Max 3000N (300Kg)
  • Connectivity via M12 quick connect 8-pin male
Part Number Part Description Voltage Connection Type Auxiliary Override Actuator
454316AZ KLM-Z-SKR-RR QC-M12 Rear Release (no manual release) – Std Actuator 24V QC-M12 No Release AZ – Standard RFID Actuator
454016AZ KLM-Z-SKR-RR QC-M12 Rear Release (side manual release) – Std Actuator 24V QC-M12 Side Only AZ – Standard RFID Actuator

Important Note
Key sold separately

Technical Data
ApprovalsTUV, cULus
Classification and Coding Level according to EN ISO 14119Type 4, High
TechnologyRFID, Power to Unlock
Housing MaterialPainted Die-Cast Metal
Head Material316 Grade Stainless Steel
Supply Voltage24Vdc (+/- 10%) SELV/PELV or Class 2
Power ConsumptionR+ (50mA Max.) / S+ (500mA Max.) (Solenoid)
Safety Circuits2 OSSD PNP Outputs (24Vdc 200mA max. switching)
Auxiliary Circuits (34 & 44)24Vdc 200mA max. Output feed
Rated Insulation Voltage500VAC
Rated Impulse withstand1000VAC
Holding Force (ISO14119)F1Max 3000N Fzh 2307N
Actuator insertion for locking5mm
Sao / Sar (RFID)15mm / 25mm
Operating Frequency1Hz
Actuator entry minimum radius175mm
Enclosure ProtectionIP67
Operating Temperature-25 ... +40 °C
Mechanical Life Expectancy (B10d)2.5 x 10 6 cycles at 100mA load
VibrationIEC68-2-6, 10-55Hz+1Hz Excursion: 0.35mm, 1 octave/min

Characteristic data according to IEC62061 (used as a subsystem)
Safety Integrity LevelSIL 3
PFH (1/h)1.0 E-09 (Corresponds to 1% of SIL3)
PFD (Av.)8.7 E-05 (Corresponds to 9% of SIL3)
Proof Test Interval T120a

Characteristic data according to EN ISO13849-1
Performance Levele
Category Cat 4
MTTFd 771a
Diagnostic Coverage DCHigh

Information with regard to UL Standards
Type 1 enclosure. Use Class 2 power supply or equivalent. Maximum temperature 40°C. Use 16-28AWG copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7Nm). Intended for same polarity use. Safety Circuits (11-12 & 21-22) 24V.dc 200mA max. Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit. (Earth bonding terminal inside metal enclosures (if required). Use 16-12AWG conductors)