KLM-Z-RR QC-M12 Guard Locking Safety Switch with RFID, OSSD, Rear Release and M12 Quick Connect
The KLM-Z-RR QC-M12 guard locking safety interlock with integrated RFID is housed in a heavy-duty die-cast enclosure and provides a holding force of up to 3000 N. Featuring OSSD outputs, the KLM-Z-RR can be connected in series while maintaining a high level of functional safety.
Four integrated LEDs provide clear device diagnostics for solenoid status, guard position, input, and output status. Designed for small to large guard doors, the KLM-Z-RR helps keep guards securely closed until hazardous motion has stopped or the hazard has been removed. The KLM-Z-RR also includes a non-latching rear release mechanism, enabling the guard lock to be released quickly from inside the guarded area in an emergency.
The uniquely coded RFID actuator provides high-level coding in accordance with ISO 14119, delivering a high level of anti-tamper protection and helping to prevent unauthorised operation.
- Body manufactured from Die-Cast Metal Painted Red
- Head manufactured from 316 Stainless Steel
- Ingress protection up to IP67
- Non-latching rear release mechanism
- High Coded RFID to ISO 14119
- 2 OSSD PNP Outputs and 2 Auxiliary Outputs (Door Position / Lock Status)
- Holding force up to F1Max 3000N (300Kg)
- Connection via M12 quick connect 8-pin male
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Part Description | Voltage | Connection Type | Auxiliary Override | Actuator |
|---|---|---|---|---|---|
| 454013AZ | KLM-Z-RR QC-M12 (manual release lid and side) – Std Actuator | 24V | QC-M12 | Lid and Side | AZ – Standard RFID Actuator |
| 454013HFZ | KLM-Z-RR QC-M12 (manual release lid and side) – Heavy Duty Actuator | 24V | QC-M12 | Lid and Side | HFZ – Stainless Steel Flexible RFID Actuator |
| 454313AZ | KLM-Z-RR QC-M12 (no release) – Std Actuator | 24V | QC-M12 | No Release | AZ – Standard RFID Actuator |
| 454313HFZ | KLM-Z-RR QC-M12 (no release) – Heavy Duty Actuator | 24V | QC-M12 | No Release | HFZ – Stainless Steel Flexible RFID Actuator |
| 454413AZ | KLM-Z-RR QC-M12 (lid only release) – Std Actuator | 24V | QC-M12 | Lid Only | AZ – Standard RFID Actuator |
| 454413HFZ | KLM-Z-RR QC-M12 (lid only release) – Heavy Duty Actuator | 24V | QC-M12 | Lid Only | HFZ – Stainless Steel Flexible RFID Actuator |
| Technical Data | |
|---|---|
| Approvals | TUV, cULus |
| Classification and Coding Level according to EN ISO 14119 | Type 4, High |
| Technology | RFID, Power to Unlock |
| Housing Material | Painted Die-Cast Metal |
| Head Material | 316 Grade Stainless Steel |
| Supply Voltage | 24Vdc (+/- 10%) SELV/PELV or Class 2 |
| Power Consumption | R+ (50mA Max.) / S+ (500mA Max.) (Solenoid) |
| Safety Circuits | 2 OSSD PNP Outputs (24Vdc 200mA max. switching) |
| Auxiliary Circuits (34 & 44) | 24Vdc 200mA max. Output feed |
| Rated Insulation Voltage | 500VAC |
| Rated Impulse withstand | 1000VAC |
| Holding Force (ISO14119) | F1Max 3000N Fzh 2307N |
| Actuator insertion for locking | 5mm |
| Sao / Sar (RFID) | 15mm / 25mm |
| Operating Frequency | 1Hz |
| Actuator entry minimum radius | 175mm |
| Enclosure Protection | IP67 |
| Operating Temperature | -25 ... +40 °C |
| Mechanical Life Expectancy (B10d) | 2.5 x 10 6 cycles at 100mA load |
| Vibration | IEC68-2-6, 10-55Hz+1Hz Excursion: 0.35mm, 1 octave/min |
| Characteristic data according to IEC62061 (used as a subsystem) | |
|---|---|
| Safety Integrity Level | SIL 3 |
| PFH (1/h) | 1.0 E-09 (Corresponds to 1% of SIL3) |
| PFD (Av.) | 8.7 E-05 (Corresponds to 9% of SIL3) |
| Proof Test Interval T1 | 20a |
| Characteristic data according to EN ISO13849-1 | |
|---|---|
| Performance Level | e |
| Category | Cat 4 |
| MTTFd | 771a |
| Diagnostic Coverage DC | High |
| Information with regard to UL Standards |
|---|
| Type 1 enclosure. Use Class 2 power supply or equivalent. Maximum temperature 40°C. Use 16-28AWG copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7Nm). Intended for same polarity use. Safety Circuits (11-12 & 21-22) 24V.dc 200mA max. Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit. (Earth bonding terminal inside metal enclosures (if required). Use 16-12AWG conductors) |