KLM-P2L QC-M23 Guard Locking Safety Switch with Power to Lock

The KLM-P2L guard-locking safety interlock features a slimline die-cast metal body and a holding force of up to 3000N, helping to keep medium to large guard doors securely closed until hazards have been removed. The guard remains locked while 24Vdc is supplied to the solenoid, providing controlled access to hazardous areas.


  • Die-cast metal construction
  • 316 stainless steel head
  • Holding force up to F1Max 3000N (300kg)
  • Functions as a power-to-lock device
  • Rotatable head provides up to 8 entry positions
  • Ingress protection up to IP67
  • Connectivity via M23 12-pin male quick connect
Part Number Part Description Voltage Connection Type Actuator
202023 KLM-P2L QC M23 24V 24V QC M23 No Actuator
202023-SS KLM-P2L QC M23 24V SS head 24V QC M23 No Actuator
202023A KLM-P2L QC M23 24V – std actuator 24V QC M23 A – Standard Actuator
202023A-SS KLM-P2L QC M23 24V SS head – std actuator 24V QC M23 A – Standard Actuator
202023F KLM-P2L QC M23 24V – flat actuator 24V QC M23 F – Flat Actuator
202023F-SS KLM-P2L QC M23 24V SS head – flat actuator 24V QC M23 F – Flat Actuator
202023HF KLM-P2L QC M23 24V – HF actuator 24V QC M23 HF – Metal Flexible Actuator
202023HF-SS KLM-P2L QC M23 24V SS head – HF actuator 24V QC M23 HF – Metal Flexible Actuator
202023HFH KLM-P2L QC M23 24V – HFH actuator 24V QC M23 HFH – Stainless Steel Flexible Actuator
202023HFH-SS KLM-P2L QC M23 24V SS head – HFH actuator 24V QC M23 HFH – Stainless Steel Flexible Actuator
202026 KLM-P2L QC M23 110V 110V QC M23 No Actuator
202026-SS KLM-P2L QC M23 110V SS Head 110V QC M23 No Actuator
202026A KLM-P2L QC M23 110V – std actuator 110V QC M23 A – Standard Actuator
202026A-SS KLM-P2L QC M23 110V SS Head – std actuator 110V QC M23 A – Standard Actuator
202026F KLM-P2L QC M23 110V – flat actuator 110V QC M23 F – Flat Actuator
202026F-SS KLM-P2L QC M23 110V SS Head – flat actuator 110V QC M23 F – Flat Actuator
202026HF KLM-P2L QC M23 110V – HF actuator 110V QC M23 HF – Metal Flexible Actuator
202026HF-SS KLM-P2L QC M23 110V SS Head – HF actuator 110V QC M23 HF – Metal Flexible Actuator
202026HFH KLM-P2L QC M23 110V – HFH actuator 110V QC M23 HFH – Stainless Steel Flexible Actuator
202026HFH-SS KLM-P2L QC M23 110V SS Head – HFH actuator 110V QC M23 HFH – Stainless Steel Flexible Actuator
202029 KLM-P2L QC M23 230V 230V QC M23 No Actuator
202029-SS KLM-P2L QC M23 230V SS Head 230V QC M23 No Actuator
202029A KLM-P2L QC M23 230V – std actuator 230V QC M23 A – Standard Actuator
202029A-SS KLM-P2L QC M23 230V SS Head – std actuator 230V QC M23 A – Standard Actuator
202029F KLM-P2L QC M23 230V – flat actuator 230V QC M23 F – Flat Actuator
202029F-SS KLM-P2L QC M23 230V SS Head – flat actuator 230V QC M23 F – Flat Actuator
202029HF KLM-P2L QC M23 230V – HF actuator 230V QC M23 HF – Metal Flexible Actuator
202029HF-SS KLM-P2L QC M23 230V SS Head – HF actuator 230V QC M23 HF – Metal Flexible Actuator
202029HFH KLM-P2L QC M23 230V – HFH actuator 230V QC M23 HFH – Stainless Steel Flexible Actuator
202029HFH-SS KLM-P2L QC M23 230V SS Head – HFH actuator 230V QC M23 HFH – Stainless Steel Flexible Actuator

Technical Data
CertificatescULus
TechnologyPower to Lock
Housing MaterialPainted Die-Cast Metal
Head MaterialPainted Die-Cast Metal or 316 Grade Stainless Steel
Solenoid Voltage24V ac/dc (12W.)
Safety Contacts 11/12 21/22 33/34Utilization Category AC15 A300 3A. Thermal Current (Ith) 5A
Overload protection fuse (fuse externally)10A. (FF)
Auxiliary Contact 43/44230V.ac/dc 0.5A. Maximum
Rated Insulation Voltage600VAC
Rated Impulse Withstand Volt2500VAC
Travel for Positive Opening10mm
Approach Speed200mm/m. to 1000mm/s
Man. Actuation Frequency2 cycle/sec
Actuator entry minimum radius175mm Standard 100mm Flexible
Enclosure ProtectionIP67
Operating Temperature-25 ... +40 °C
Holding ForceF1Max: 3000N. Fzh: 2307N
VibrationIEC 68-2-6, 10-55Hz+1Hz, Excursion: 0.35mm, 1 octave/min
Conduit EntryM23 Quick Connect 12-Pin Male
Fixing4 x M5

Safety Classification and Reliability Data
Mechanical Reliability B10d2.5 x 106 operations at 100mA load
ISO 13849-1up to PLe / Cat.4 depending upon system architecture
EN 62061up to SIL3 depending upon system architecture
Safety Data - Annual Usage8 cycles per hour / 24 hours per day / 365 days
PFHd3.44 x 10-8
Proof Test Interval (Life)35 years
MTTFd356 years

Information with regard to UL Standards
Type 1 enclosure. Maximum temperature 40°C. Use 16-28AWG stranded copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7Nm). Intended for same polarity use. A300 Pilot Duty. 240V. 3A. PF 0.38 or greater, tested for 6,000 cycles endurance Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit.