KL3-SS-P2L Guard Locking Safety Switch with Power to Lock

The KL3-SS-P2L is a power-to-lock guard-locking safety interlock with a hygienic, mirror-polished 316 stainless steel body. With a holding force of up to 3000 N, it is designed to keep medium to large guard doors securely closed until hazardous motion or processes have stopped.

It is suitable for applications requiring strict washdown procedures, including high-temperature, high-pressure washing and exposure to corrosive cleaning chemicals.

 

  • Body manufactured from Mirror Polished 316 Grade Stainless Steel
  • Holding Force up to  F1Max 3000N (300Kg)
  • Power-to-lock operation
  • Rotating head for up to 8 entry positions
  • Ingress Protection up to IP69K
  • Conduit: 3 x M20 or ½” NPT (Quick Connect Available)
Part No. Part Description Voltage Conduit Type Actuator
205021 KL3-SS-P2L- M20 24v 24v M20 No Actuator
205021A KL3-SS-P2L M20 24v – std actuator 24v M20 A – Standard Actuator
205021F KL3-SS-P2L M20 24v – flat actuator 24v M20 F – Flat Actuator
205021HF KL3-SS-P2L M20 24v – HF actuator 24v M20 HF – Metal Flexible Actuator
205021HFH KL3-SS-P2L M20 24v – HFH actuator 24v M20 HFH – Stainless Steel Flexible Actuator
205022 KL3-SS-P2L ½NPT 24v 24v ½NPT No Actuator
205022A KL3-SS-P2L ½NPT 24v – std actuator 24v ½NPT A – Standard Actuator
205022F KL3-SS-P2L ½NPT 24v – flat actuator 24v ½NPT F – Flat Actuator
205022HF KL3-SS-P2L ½NPT 24v – HF Actuator 24v ½NPT HF – Metal Flexible Actuator
205022HFH KL3-SS-P2L ½NPT 24v – HFH Actuator 24v ½NPT HFH – Stainless Steel Flexible Actuator
205025A KL3-SS-P2L ½NPT 110v – std actuator 110v ½NPT A – Standard Actuator

Note
Suitable for Splash Zones in accordance with EHEDG guidelines.

Technical Data
CertificatescULus
TechnologyPower to Lock
Housing Material316 Grade Stainless Steel
Solenoid Voltage24V ac/dc (12W.)
Safety Contacts 11/12 21/22 33/34Utilization Category AC15 A300 3A. Thermal Current (Ith) 5A
Overload protection fuse (fuse externally)10A. (FF)
Auxiliary Contact 43/44230V.ac/dc 0.5A. Maximum
Rated Insulation Voltage600VAC
Rated Impulse Withstand Volt2500VAC
Travel for Positive Opening10mm
Approach Speed200mm/m. to 1000mm/s
Man. Actuation Frequency2 cycle/sec
Actuator entry minimum radius175mm Standard 100mm Flexible
Enclosure ProtectionIP67, IP69K
Operating Temperature-25 ... +40 °C
Holding ForceF1Max: 3000N. Fzh: 2307N
VibrationIEC 68-2-6, 10-55Hz+1Hz, Excursion: 0.35mm, 1 octave/min
Conduit EntryM20 or 1/2" NPT
Fixing4 x M5

Safety Classification and Reliability Data
Mechanical Reliability B10d2.5 x 106 operations at 100mA load
ISO 13849-1up to PLe / Cat.4 depending upon system architecture
EN 62061up to SIL3 depending upon system architecture
Safety Data - Annual Usage8 cycles per hour / 24 hours per day / 365 days
PFHd3.44 x 10-8
Proof Test Interval (Life)35 years
MTTFd356 years

Information with regard to UL Standards
Type 1 enclosure. Maximum temperature 40°C. Use 16-28AWG stranded copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7Nm). Intended for same polarity use. A300 Pilot Duty. 240V. 3A. PF 0.38 or greater, tested for 6,000 cycles endurance Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit.