KL3-SS-P2L QC-M23 Guard Locking Safety Switch with Power to Lock and M23 Quick Connect

The KL3-SS-P2L QC M23 is a power-to-lock guard-locking safety interlock with a hygienic, mirror-polished 316 stainless steel body. With a holding force of up to 3000 N, it is designed to keep medium to large guard doors securely closed until hazardous motion or processes have stopped.

It is suitable for applications requiring strict washdown procedures, including high-temperature, high-pressure washing and exposure to corrosive cleaning chemicals.

 

  • Body manufactured from Mirror Polished 316 Grade Stainless Steel
  • Holding Force up to  F1Max 3000N (300Kg)
  • Power-to-lock operation
  • Rotating head for up to 8 entry positions
  • Ingress Protection up to IP69K
  • Connectivity via M23 12-pin male connector
Part Number Part Description Voltage Connector Type Actuator
205023 KL3-SS-P2L QC M23 12way 24v 24v QC M23 12way No Actuator
205023A KL3-SS-P2L QC M23 12way 24v – std actuator 24v QC M23 12way A – Standard Actuator
205023F KL3-SS-P2L QC M23 12way 24v – flat actuator 24v QC M23 12way F – Flat Actuator
205023HF KL3-SS-P2L QC M23 12way 24v – HF actuator 24v QC M23 12way HF – Metal Flexible Actuator
205023HFH KL3-SS-P2L QC M23 12way 24v – HFH actuator 24v QC M23 12way HFH – Stainless Steel Flexible Actuator

Note
Suitable for Splash Zones in accordance with EHEDG guidelines.

Technical Data
CertificatescULus
TechnologyPower to Lock
Housing Material316 Grade Stainless Steel
Solenoid Voltage24V ac/dc (12W.)
Safety Contacts 11/12 21/22 33/34Utilization Category AC15 A300 3A. Thermal Current (Ith) 5A
Overload protection fuse (fuse externally)10A. (FF)
Auxiliary Contact 43/44230V.ac/dc 0.5A. Maximum
Rated Insulation Voltage600VAC
Rated Impulse Withstand Volt2500VAC
Travel for Positive Opening10mm
Approach Speed200mm/m. to 1000mm/s
Man. Actuation Frequency2 cycle/sec
Actuator entry minimum radius175mm Standard 100mm Flexible
Enclosure ProtectionIP67, IP69K
Operating Temperature-25 ... +40 °C
Holding ForceF1Max: 3000N. Fzh: 2307N
VibrationIEC 68-2-6, 10-55Hz+1Hz, Excursion: 0.35mm, 1 octave/min
Conduit EntryM20 or 1/2" NPT
Fixing4 x M5

Safety Classification and Reliability Data
Mechanical Reliability B10d2.5 x 106 operations at 100mA load
ISO 13849-1up to PLe / Cat.4 depending upon system architecture
EN 62061up to SIL3 depending upon system architecture
Safety Data - Annual Usage8 cycles per hour / 24 hours per day / 365 days
PFHd3.44 x 10-8
Proof Test Interval (Life)35 years
MTTFd356 years

Information with regard to UL Standards
Type 1 enclosure. Maximum temperature 40°C. Use 16-28AWG stranded copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7Nm). Intended for same polarity use. A300 Pilot Duty. 240V. 3A. PF 0.38 or greater, tested for 6,000 cycles endurance Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit.