KL1-P QC-M12 Guard Locking Safety Switch with M12 Quick Connect

The KL1-P (LEILOCK) guard locking safety interlock features a compact plastic body and a holding force of up to 1400N to keep small to medium guard doors closed until hazards have been removed.


  • Body manufactured from High Specification Polyester – Red
  • Head manufactured from 316 Stainless Steel
  • Holding Force up to F1Max 1400N (140Kg)
  • Actuation via Rotating head for up to 4 entry positions
  • Ingress Protection up to IP67
  • Connectivity via Integrated M12 8way connector with 250mm pigtail and gland
Part No. Part Description Voltage Connectivity Actuator
221003 KL1-P QC M12 8way 24v LED only 24v QC M12 8way No Actuator
221003A KL1-P QC M12 8way 24v LED only – std actuator 24v QC M12 8way A – Standard Actuator
221003F KL1-P QC M12 8way 24v LED only – flat actuator 24v QC M12 8way F – Flat Actuator
221003HF KL1-P QC M12 8way 24v LED only – HF actuator 24v QC M12 8way HF – Metal Flexible Actuator
221003HFH KL1-P QC M12 8way 24v LED only – HFH actuator 24v QC M12 8way HFH – Stainless Steel Flexible Actuator
221006 KL1-P QC M12 8way 110v LED only 110v QC M12 8way No Actuator
221006A KL1-P QC M12 8way 110v LED only – std actuator 110v QC M12 8way A – Standard Actuator
221006F KL1-P QC M12 8way 110v LED only – flat actuator 110v QC M12 8way F – Flat Actuator
221006HF KL1-P QC M12 8way 110v LED only – HF actuator 110v QC M12 8way HF – Metal Flexible Actuator
221006HFH KL1-P QC M12 8way 110v LED only – HFH actuator 110v QC M12 8way HFH – Stainless Steel Flexible Actuator
221009 KL1-P QC M12 8way 230v LED only 230v QC M12 8way No Actuator
221009A KL1-P QC M12 8way 230v LED only – std actuator 230v QC M12 8way A – Standard Actuator
221009F KL1-P QC M12 8way 230v LED only – flat actuator 230v QC M12 8way F – Flat Actuator
221009HF KL1-P QC M12 8way2 230v LED only – HF actuator 230v QC M12 8way HF – Metal Flexible Actuator
221009HFH KL1-P QC M12 8way 230v LED only – HFH actuator 230v QC M12 8way HFH – Stainless Steel Flexible Actuator

Note
The LED-only version provides guard status indication through a single LED, with lock status monitored separately via a normally closed output

Technical Data
CertificatescULus
Technology Power to Unlock
Housing MaterialRed Polyester
Head Material316 Grade Stainless Steel
Solenoid Voltage (by part number)24V ac/dc or 110V. ac or 230V. ac +/- 10% (12W.)
LED 2 (if fitted) Supply Voltage24V dc +/- 10%
Safety Contacts 11/12 21/22Utilization Category AC15 A300 3A. Thermal Current (Ith) 5A
Overload protection fuse (fuse externally)10A. (FF)
Auxiliary Contact 33/3424V.ac/dc 0.5A. Maximum
Auxiliary Contact 43/44230V.ac/dc 0.5A. Maximum
Rated Insulation Voltage600VAC
Rated Impulse Withstand Volt2500VAC
Travel for Positive Opening10mm
Approach Speed200mm/m. to 1000mm/s
Man. Actuation Frequency2 cycle/sec
Actuator entry minimum radius175mm Standard 100mm Flexible
Enclosure ProtectionIP67
Operating Temperature-25 ... +40 °C
Holding ForceF1Max: 2000N. Fzh: 1538N
VibrationIEC 68-2-6, 10-55Hz+1Hz, Excursion: 0.35mm, 1 octave/min
Conduit EntryM20 or 1/2" NPT
Fixing4 x M5

Information with regard to UL Standards
EnclosureType 1
Maximum temperature +40 °C
Terminal Torquee 6 lb ins. (0.7Nm)
Use 16-28AWG stranded copper conductors (rated 90°C)
Intended for same polarity use. A300 Pilot Duty. 240V. 3A
PF 0.38 or greater, tested for 6,000 cycles endurance
Use one polymeric conduit connection
Not suitable for connection to rigid metal conduit
KL1-P Earth bonding terminal inside enclosure if required, use 16-12AWG conductors)