KL1-P QC-M12 Guard Locking Safety Switch with M12 Quick Connect
The KL1-P (LEILOCK) guard locking safety interlock features a compact plastic body and a holding force of up to 1400N to keep small to medium guard doors closed until hazards have been removed.
- Body manufactured from High Specification Polyester – Red
- Head manufactured from 316 Stainless Steel
- Holding Force up to F1Max 1400N (140Kg)
- Actuation via Rotating head for up to 4 entry positions
- Ingress Protection up to IP67
- Connectivity via Integrated M12 8way connector with 250mm pigtail and gland
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part No. | Part Description | Voltage | Connectivity | Actuator |
|---|---|---|---|---|
| 221003 | KL1-P QC M12 8way 24v LED only | 24v | QC M12 8way | No Actuator |
| 221003A | KL1-P QC M12 8way 24v LED only – std actuator | 24v | QC M12 8way | A – Standard Actuator |
| 221003F | KL1-P QC M12 8way 24v LED only – flat actuator | 24v | QC M12 8way | F – Flat Actuator |
| 221003HF | KL1-P QC M12 8way 24v LED only – HF actuator | 24v | QC M12 8way | HF – Metal Flexible Actuator |
| 221003HFH | KL1-P QC M12 8way 24v LED only – HFH actuator | 24v | QC M12 8way | HFH – Stainless Steel Flexible Actuator |
| 221006 | KL1-P QC M12 8way 110v LED only | 110v | QC M12 8way | No Actuator |
| 221006A | KL1-P QC M12 8way 110v LED only – std actuator | 110v | QC M12 8way | A – Standard Actuator |
| 221006F | KL1-P QC M12 8way 110v LED only – flat actuator | 110v | QC M12 8way | F – Flat Actuator |
| 221006HF | KL1-P QC M12 8way 110v LED only – HF actuator | 110v | QC M12 8way | HF – Metal Flexible Actuator |
| 221006HFH | KL1-P QC M12 8way 110v LED only – HFH actuator | 110v | QC M12 8way | HFH – Stainless Steel Flexible Actuator |
| 221009 | KL1-P QC M12 8way 230v LED only | 230v | QC M12 8way | No Actuator |
| 221009A | KL1-P QC M12 8way 230v LED only – std actuator | 230v | QC M12 8way | A – Standard Actuator |
| 221009F | KL1-P QC M12 8way 230v LED only – flat actuator | 230v | QC M12 8way | F – Flat Actuator |
| 221009HF | KL1-P QC M12 8way2 230v LED only – HF actuator | 230v | QC M12 8way | HF – Metal Flexible Actuator |
| 221009HFH | KL1-P QC M12 8way 230v LED only – HFH actuator | 230v | QC M12 8way | HFH – Stainless Steel Flexible Actuator |
| Note |
|---|
| The LED-only version provides guard status indication through a single LED, with lock status monitored separately via a normally closed output |
| Technical Data | |
|---|---|
| Certificates | cULus |
| Technology | Power to Unlock |
| Housing Material | Red Polyester |
| Head Material | 316 Grade Stainless Steel |
| Solenoid Voltage (by part number) | 24V ac/dc or 110V. ac or 230V. ac +/- 10% (12W.) |
| LED 2 (if fitted) Supply Voltage | 24V dc +/- 10% |
| Safety Contacts 11/12 21/22 | Utilization Category AC15 A300 3A. Thermal Current (Ith) 5A |
| Overload protection fuse (fuse externally) | 10A. (FF) |
| Auxiliary Contact 33/34 | 24V.ac/dc 0.5A. Maximum |
| Auxiliary Contact 43/44 | 230V.ac/dc 0.5A. Maximum |
| Rated Insulation Voltage | 600VAC |
| Rated Impulse Withstand Volt | 2500VAC |
| Travel for Positive Opening | 10mm |
| Approach Speed | 200mm/m. to 1000mm/s |
| Man. Actuation Frequency | 2 cycle/sec |
| Actuator entry minimum radius | 175mm Standard 100mm Flexible |
| Enclosure Protection | IP67 |
| Operating Temperature | -25 ... +40 °C |
| Holding Force | F1Max: 2000N. Fzh: 1538N |
| Vibration | IEC 68-2-6, 10-55Hz+1Hz, Excursion: 0.35mm, 1 octave/min |
| Conduit Entry | M20 or 1/2" NPT |
| Fixing | 4 x M5 |
| Information with regard to UL Standards | |
|---|---|
| Enclosure | Type 1 |
| Maximum temperature | +40 °C |
| Terminal Torque | e 6 lb ins. (0.7Nm) |
| Use 16-28AWG stranded copper conductors (rated 90°C) | |
| Intended for same polarity use. A300 Pilot Duty. 240V. 3A | |
| PF 0.38 or greater, tested for 6,000 cycles endurance | |
| Use one polymeric conduit connection | |
| Not suitable for connection to rigid metal conduit | |
| KL1-P Earth bonding terminal inside enclosure if required, use 16-12AWG conductors) |