NET-BOX-PS Stainless Steel with PROFINET PROFIsafe
NET-BOX-PS-SS control station with integrated PROFINET with PROFIsafe provides up to 6 configurable machine control functions and 4 additional M12 connectors for field devices and distributed I/O. The compact design and robust stainless steel enclosure are suitable for external mounting, ensuring simple and cost-effective connectivity.
- Three Dual Channel Safety Inputs
- Up to 40+ Non-Safe I/O
- Integrated PROFINET Safety Network Switch
- IP65 enclosure (IP69K with button covers)
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Description | Conduits |
|---|---|---|
| 532001 | NET-BOX-PS-SS M20 STAINLESS STEEL | M20 |
| 532002 | NET-BOX-PS-SS 1/2" NPT STAINLESS STEEL | 1/2" NPT |
| Technical Data | |
|---|---|
| Body Material | 316 Grade Stainless Steel |
| Response time (Safety Inputs) | 36 ms max. (Change of input state -> transmission to field bus) |
| Response time (Safety Outputs) | 7.7 ms max. (field bus telegram recv’d -> change of output state) |
| Operating voltage | 24 V DC +10%/-15% (SELV/PELV) |
| Power Supply UL Requirements | Class 2 power supply must be used |
| Current consumption, max | 250 mA (excluding Standard Outputs and Safety Outputs) |
| Allowed through current (daisy-chain) | 5A |
| Input Rated Voltage | 24V DC |
| Input Rated Current | 2 mA |
| Output Rated Voltage | 24V DC (sourced from power connectors) |
| Output Maximum Current | 500 mA single / 1.5 A group (OUT1..4 / OUT5..8) |
| Operating temperature | -20 °C to 40 °C |
| Enclosure Protection | IP65 (IP69K with button covers) IP67 at the connectors |
| Maximum operating altitude | 2000 m |
| Shock and Vibration | Tested in accordance with: IEC 60068-2-6 and IEC 60068-2-27 |
| Pollution Degree | Degree 2 (EN 60664) (Storage and Operation) |
| Reliability / Safety Data (EN ISO 13849-1) | |
|---|---|
| Category | 4 |
| Performance Level | e |
| MTTFd | High |
| DC | >90% |
| Reliability / Safety Data (EN 62061 / IEC 61508) | |
|---|---|
| Mission Time | 20 years |
| SIL CL | SIL 3 |
| PFHd (Emergency Stop Function) | 2.3E-9 |
| PFHd Safety Inputs (voltage free contacts with test pulses) | 2.4E-9 |
| PFHd Safety Inputs (OSSD inputs to device) | 2.4E-9 |
| PFHd Safety Outputs | 2.4E-9 |