Standalone Coded Non-Contact Safety Switch (MSA)
The MSA safety switch is a standalone, non-contact device with self-monitoring, force-guided mechanical contacts that maintains high functional safety levels even when connected in series, and it can be installed on guard doors without the need for additional safety monitoring equipment.
- Material: Mirror Polished 316 Stainless Steel
- Contacts: 2 N/C + 1 N/O (Voltage-Free)
- Safety Outputs: 2 Force Guided Safety Outputs
- Ingress Protection: IP69K
- Connection: Pre-Wired or M12 8 Pole Quick Connect (QC)
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Description | Safety Outputs | Auxiliary | Reset Mode | Connectivity |
|---|---|---|---|---|---|
| 130002 | MSA S/Steel 316 5M | 2 (1 Force Guided Relay) | 1 | Automatic or Manual | 5M Pre-Wired |
| 130003 | MSA S/Steel 316 10M | 2 (1 Force Guided Relay) | 1 | Automatic or Manual | 10M Pre-Wired |
| 130004 | MSA S/Steel 316 QC-M12 8way (Automatic Start) | 2 (1 Force Guided Relay) | 1 | Automatic | 250mm Pigtail M12-QC 8way |
| 130005 | MSA S/Steel 316 QC-M12 8way (Manual Start) | 2 (1 Force Guided Relay) | 1 | Manual | 250mm Pigtail M12-QC 8way |
| Technical Data | |
|---|---|
| Approvals | TUV, cULus |
| Coding Level according to EN ISO 14119 | Low |
| Technology | Coded Magnetic, Hall effect |
| Housing Material | 316 Grade Stainless Steel |
| Power Supply | 24Vdc +/-10% (Consumption 150mA max.) |
| NC Safety Output Max.Rating | 240Vac/24Vdc 3A* ac/dc (*Max. current for QC is 2A) |
| NO Auxiliary Output Max.Rating | 24Vdc 0.5A |
| Recommended Setting Gap | 5mm |
| Switching Distance | Sao 10mm Close / Sar 25mm Open |
| Tolerance to Misalignment | 5mm in any direction from 5mm setting gap |
| Approach Speed | 600mm/m to 1000mm/s |
| Temperature | -25 ... +45 °C |
| Cable | PVC 10 core 7mm OD |
| IP Rating | IP67, IP69K (M12 connector rated to IP67) |
| Characteristic Data according to IEC62061 (used as a sub system) | |
|---|---|
| Safety Integrity Level | SIL3 |
| PFH (1/h) | 3.95E-10 (Corresponds to 4.0% of SIL3) |
| PFD | 3.46E-05 (Corresponds to 3.5% of SIL3) |
| Proof Test Interval T1 | 20a |
| Information with regard to UL 508 | |
|---|---|
| Enclosure | Type 1 |
| NC Maximum Output | 24Vdc 3A |
| NO Maximum Output | 24V.dc 0.5A |
| Use Class 2 Supply or equivalent |