Leading Manufacturer of Safety Interlock Switches and Machine Guard Safety Switch Devices for Automation and Process Safety

RFID Non-Contact Safety Interlock Switch (KPF)

The KPF is an RFID machine guard safety switch that uses RFID technology to detect the presence of a guard and ensure safe operation of machinery.

  • Housing/Fixing: Industry Standard, Tongue Switch Body Style
  • Contacts: 2 N/C + 1 N/O
  • Sensing Distance: 8mm ON / 20mm OFF (On Two Faces)
  • Connection: Pre-Wired or M12 8-Pole Quick Connect (Three Cable Entry Positions)
  • Indication: Single LED for Guard and RFID Code Status
  • Switching capability: 0.2A (Requires 24Vdc supply to operate)

NOTE: Designed with an industry standard fixing (52mm wide, 98mm long and 40mm) they are especially advantageous when: Severe guard alignment exists using traditional tongue type versions and long mechanical life is required (no moving or contact parts).

Part No.Part Description
408001KPF Unique End Pre-wired 5M
408002KPF Unique End Pre-wired 10M
408003KPF Unique End Pre-wired QC M12
408004KPF Unique Left Pre-wired 5M
408005KPF Unique Left Pre-wired 10M
408006KPF Unique Left Pre-wired QC M12
408007KPF Unique Right Pre-wired 5M
408008KPF Unique Right Pre-wired 10M
408009KPF Unique Right Pre-wired QC M12
408101KPF Master End Pre-wired 5M
408102KPF Master End Pre-wired 10M
408103KPF Master End Pre-wired QC M12
408104KPF Master Left Pre-wired 5M
408105KPF Master Left Pre-wired 10M
408106KPF Master Left Pre-wired QC M12
408107KPF Master Right Pre-wired 5M
408108KPF Master Right Pre-wired 10M
408109KPF Master Right Pre-wired QC M12
408201Replacement Actuator Master Coded

Technical Data
ApprovalsTUV, cULus
Coding Level according to EN ISO 14119M = Medium / U = High
TechnologyRFID
Housing MaterialRed, Polyester
Normally Closed ContactsUp to 2 N/C Safety (When the Guard is Closed)
Normally Open ContactsUp to 1 N/O Auxiliary (When the Guard is Closed)
Switching DistanceSao 8mm / Sar 20mm
Tolerance to Misalignment5mm in any Direction from 5mm Setting Gap
IndicationGreen LED when Guard is Closed
Connectivity2m, 5m, 10m, M12 QC
Length98mm
Width58mm
Height32mm
IP RatingIP67
Ambient Temperature-25 ... +55 °C
Storage Temperature-25 ... +55 °C
Supply24VDC +/- 10%
Maximum Switched Current (Outputs)200mA (Minimum Internal Resistance 8.5ohms)
Switching Frequency1.0 Hz Maximum
Approach Speed200mm/m. to 1000mm/s.
CablePVC 6mm O.D. Conductors 0.25 sq.mm

Characteristic Data according to IEC62061 (used as a sub system)
Safety Integrity LevelSIL3
PFH (1/h)4.77E-10 (Corresponds to 4.8% of SIL3)
PFD4.18E-05 (Corresponds to 4.2% of SIL3)
Proof Test Interval T120a

Characteristic Data according to EN ISO13849-1
Performance Levele (If both channels are used in combination with a SIL3/PLe control device)
CategoryCat4
MTTFd1100a
Diagnostic Coverage DC 99% (high)

Information with regard to UL 508
EnclosureType 1
Maximum Temperature +50 °C
Maximum Output24V.dc 100mA
Powered by Class 2 or equivalent.