RFID Non-Contact Safety Interlock Switch (BPF:M18)
The BPF is an RFID machine guard safety switch that uses RFID technology to detect the presence of a guard and ensure safe operation of machinery. The M18 design is compact and versatile, suitable for mounting directly into machine guard frames.
- Housing/Fixing: M18 Threaded Barrell
- Contacts: 2 N/C + 1 N/O
- Sensing Distance: 8mm ON / 20mm OFF
- Connection: Pre-Wired or M12 8-Pole Quick Connect
- Indication: Single LED for Guard and RFID Code Status
- Switching capability: 0.2A (Requires 24Vdc supply to operate)
NOTE: Supplied with fixing nuts
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part No. | Part Description |
|---|---|
| 413001 | BPF Master Coded RFID 5M |
| 413002 | BPF Master Coded RFID 10M |
| 413003 | BPF Master Coded RFID QC-M12 |
| 413200 | Replacement Actuator Master Coded |
| 413101 | BPF Uniquely Coded RFID 5M |
| 413102 | BPF Uniquely Coded RFID 10M |
| 413103 | BPF Uniquely Coded RFID QC-M12 |
| Technical Data | |
|---|---|
| Approvals | TUV, cULus |
| Coding Level according to EN ISO 14119 | M = Medium / U = High |
| Technology | RFID |
| Housing Material | Red, Polyester |
| Normally Closed Contacts | Up to 2 N/C Safety (When the Guard is Closed) |
| Normally Open Contacts | Up to 1 N/O Auxiliary (When the Guard is Closed) |
| Switching Distance | Sao 8mm / Sar 20mm |
| Tolerance to Misalignment | 5mm in any Direction from 5mm Setting Gap |
| Indication | Green LED when Guard is Closed |
| Connectivity | 2m, 5m, 10m, M12 QC |
| Length | 73mm |
| Diameter | M18 x 1 |
| IP Rating | IP67 |
| Ambient Temperature | -25 ... +55 °C |
| Storage Temperature | -25 ... +55 °C |
| Supply | 24VDC +/- 10% |
| Maximum Switched Current (Outputs) | 200mA (Minimum Internal Resistance 8.5ohms) |
| Switching Frequency | 1.0 Hz Maximum |
| Approach Speed | 200mm/m. to 1000mm/s. |
| Cable | PVC 6mm O.D. Conductors 0.25 sq.mm |
| Characteristic Data according to IEC62061 (used as a sub system) | |
|---|---|
| Safety Integrity Level | SIL3 |
| PFH (1/h) | 4.77E-10 (Corresponds to 4.8% of SIL3) |
| PFD | 4.18E-05 (Corresponds to 4.2% of SIL3) |
| Proof Test Interval T1 | 20a |
| Characteristic Data according to EN ISO13849-1 | |
|---|---|
| Performance Level | e (If both channels are used in combination with a SIL3/PLe control device) |
| Category | Cat4 |
| MTTFd | 1100a |
| Diagnostic Coverage DC | 99% (high) |
| Information with regard to UL 508 | |
|---|---|
| Enclosure | Type 1 |
| Maximum Temperature | +50 °C |
| Maximum Output | 24V.dc 100mA |
| Powered by Class 2 or equivalent. |




