Magnetic Non-Contact Safety Interlock Switch (LMR)

HYGIEMAG non-contact, magnetic safety interlock switches are designed for use on machinery and equipment to ensure the safety of the operators and prevent accidents. The LMR is housed in a robust, 316 stainless steel enclosure and tested to IP69K, suitable for washdown applications.


  • Narrow Design for Flush Mounting
  • Laser Etched Markings
  • Contact Configurations up to 3NC or 2NC + 1NO
  • 1A ac/dc Switching Capability
  • Connectivity via Pre-Wired PVC Cable or M12 Quick Connect
Part Number Part Description Safety Auxiliary Connection
133009 LMR 2M ‘2NC’ 2NC 0 2M PRE-WIRED
133010 LMR 5M ‘2NC’ 2NC 0 5M PRE-WIRED
133011 LMR 10M ‘2NC’ 2NC 0 10M PRE-WIRED
133012 LMR QC M12 8way ‘2NC’ 2NC 0 250mm Leaded M12 8way
133013 LMR 2M ‘2NC 1NO’ 2NC 1NO 2M PRE-WIRED
133014 LMR 5M ‘2NC 1NO’ 2NC 1NO 5M PRE-WIRED
133015 LMR 10M ‘2NC 1NO’ 2NC 1NO 10M PRE-WIRED
133016 LMR QC M12 8way ‘2NC 1NO’ 2NC 1NO 250mm Leaded M12 8way
133131 LMR 2M ‘3NC’ 3NC 0 2M PRE-WIRED
133132 LMR 5M ‘3NC’ 3NC 0 5M PRE-WIRED
133133 LMR 10M ‘3NC’ 3NC 0 10M PRE-WIRED
133134 LMR QC M12 8way ‘3NC’ 3NC 0 250mm Leaded M12 8way

Note
Suitable for Splash Zones in accordance with EHEDG guidelines.

Technical Data
CertificatesTUV, cULus
Coding Level according to EN ISO 14119Low
TechnologyMagnetic
Housing Material316 Grade Stainless Steel
Normally Closed ContactsUp to 2 N/C Safety (When the Guard is Closed)
Normally Open ContactsUp to 1 N/O Auxiliary (When the Guard is Closed)
Contact Release Time<2ms
Tolerance to Misalignment5mm in any direction from 5mm setting gap
Connectivity2m, 5m, 10m, M12 QC
Length88mm
Width25mm
Height14mm
IP RatingIP67, IP69K
Ambient Temperature-25 ... +105 °C
Storage Temperature-25 ... +105 °C
Switching Current, Minimum10V. Dc 1mA
Switching Voltage, Maximum (2NC)240V.ac / 24V.dc 1.0A. max. Fuse externally 0.8(F)
Auxiliary Circuits (NO)24V.ac/dc 0.2A. max.
Switching Frequency1.0Hz max.
Approach Speed200mm/m. to 1000mm/s
CablePVC 6.0mm OD Conductors 0.25 sq.mm

Safety Classification and Reliability Data
ISO 13849-1Up to PLe Category 4 (if both channels are used with a PLe control device)
B10d3,300,000 cycles at 100mA load
Usage8 cycles/hour 24 hours/365 days per year MTTFd is 470 years