Magnetic Non-Contact Safety Interlock Switch (CMR-F)

HYGIEMAG non-contact, magnetic safety interlock switches are designed for use on machinery and equipment to ensure the safety of the operators and prevent accidents. The CMR-F is housed in a robust, 316 stainless steel enclosure and tested to IP69K, suitable for washdown applications. (-F) versions feature a unique hygienic design with rear fixing/mounting. This provides a smooth front surface that is easier to clean and removes any potential contamination traps.


  • Slimline Profile with Hygienic Mounting (-F)
  • Laser Etched Markings
  • Contact Configurations up to 2NC + 1NO
  • Large Sensing Distance up to 12mm
  • 1A Switching Capability or 2A on Heavy-Duty Versions (ac/dc)
  • Connectivity via Pre-Wired PVC Cable or M12 Quick Connect
Part No. Description Safety Auxiliary Connection
135017 CMR-F 2M ‘2NC’ 2NC 0 2M PRE-WIRED
135018 CMR-F 5M ‘2NC’ 2NC 0 5M PRE-WIRED
135019 CMR-F 10M ‘2NC’ 2NC 0 10M PRE-WIRED
135020 CMR-F QC M12 8way ‘2NC’ 2NC 0 250mm Leaded M12 8way
135021 CMR-F 2M ‘2NC 1NO’ 2NC 1NO 2M PRE-WIRED
135022 CMR-F 5M ‘2NC 1NO’ 2NC 1NO 5M PRE-WIRED
135023 CMR-F 10M ‘2NC 1NO’ 2NC 1NO 10M PRE-WIRED
135024 CMR-F QC M12 8way ‘2NC 1NO’ 2NC 1NO 250mm Leaded M12 8way
135025 CMR-F Heavy Duty 2M ‘1NC’ 1NC 0 2M PRE-WIRED
135026 CMR-F Heavy Duty 5M ‘1NC’ 1NC 0 5M PRE-WIRED
135027 CMR-F Heavy Duty 10M ‘1NC’ 1NC 0 10M PRE-WIRED
135028 CMR-F Heavy Duty QC M12 8way ‘1NC’ 1NC 0 250mm Leaded M12 8way
135029 CMR-F Heavy Duty 2M ‘1NC 1NO’ 1NC 1NO 2M PRE-WIRED
135030 CMR-F Heavy Duty 5M ‘1NC 1NO’ 1NC 1NO 5M PRE-WIRED
135031 CMR-F Heavy Duty 10M ‘1NC 1NO’ 1NC 1NO 10M PRE-WIRED
135032 CMR-F Heavy Duty QC M12 8way ‘1NC 1NO’ 1NC 1NO 250mm Leaded M12 8way
135131 CMR-F 2M ‘3NC’ 3NC 0 2M PRE-WIRED
135132 CMR-F 5M ‘3NC’ 3NC 0 5M PRE-WIRED
135133 CMR-F 10M ‘3NC’ 3NC 0 10M PRE-WIRED
135134 CMR-F QC M12 8way ‘3NC’ 3NC 0 250mm Leaded M12 8way

Note
Suitable for Direct Contact Zones in accordance with EHEDG guidelines.
Suitable for CIP / SIP cleaning with mounting holes at the rear thereby not creating food traps.

Technical Data
CertificatesTUV, cULus
Coding Level according to EN ISO 14119 Low
TechnologyMagnetic
Housing Material316 Grade Stainless Steel
Normally Closed ContactsUp to 2 N/C Safety (When the Guard is Closed)
Normally Open ContactsUp to 1 N/O Auxiliary (When the Guard is Closed)
Contact Release Time<2ms
Tolerance to Misalignment5mm in any Direction from 5mm Setting Gap
Connectivity2m, 5m, 10m, M12 QC
Length85mm
Width20.6mm
Height17mm
IP RatingIP67, IP69K
Ambient Temperature-25 ... +105 °C
Storage Temperature-25 ... +105 °C
Switching Current, Minimum10V. Dc 1mA
Switching Voltage, Maximum (2NC)240V.ac / 24V.dc 1.0A. max. (Fuse externally 0.8A. (F).
Switching Voltage, Maximum (1NC) 240V.ac / 24V.dc 2.0A. max. (Fuse externally 1.6A. (F).
Auxiliary Circuits (NO)24V.ac/dc 0.2A. max.
Switching Frequency1.0Hz max.
Approach Speed200mm/m. to 1000mm/s.
CablePVC 6.0mm OD Conductors 0.25 sq.mm

Safety Classification and Reliability Data
ISO 13849-1Up to PLe Category 4 (if both channels are used with a PLe control device)
B10d3,300,000 cycles at 100mA load
Usage8 cycles/hour 24 hours/365 days per year MTTFd is 470 years