Magnetic Non-Contact Safety Interlock Switch (CPR)

IDEMAG are non-contact, magnetic safety switches designed for use on machinery and equipment to ensure the safety of the operators and prevent accidents. The CPR has a slim line profile suitable for installation on narrow guard frames.

  • Industry Standard, Slim Line Housing
  • Contact Configuration up to 2 N/C + 1 N/O
  • Wide 12mm Operation
  • Connection via Pre-Wired Cable or M12 Quick Connect
  • 1A or (High Power 2A ac/dc) Switch Capacity
Part NumberPart DescriptionSafetyAuxiliaryConnection
113001CPR 2M ‘2NC’2NC02M PRE-WIRED
113002CPR 5M ‘2NC’2NC05M PRE-WIRED
113003CPR 10M ‘2NC’2NC010M PRE-WIRED
113004CPR QC M12 8way ‘2NC’2NC0250mm Leaded M12 8way
113005CPR 2M ‘2NC 1NO’2NC1NO2M PRE-WIRED
113006CPR 5M ‘2NC 1NO’2NC1NO5M PRE-WIRED
113007CPR 10M ‘2NC 1NO’2NC1NO10M PRE-WIRED
113008CPR QC M12 8way ‘2NC 1NO’2NC1NO250mm Leaded M12 8way
113009CPR Heavy Duty 2M ‘1NC’1NC02M PRE-WIRED
113010CPR Heavy Duty 5M ‘1NC’1NC05M PRE-WIRED
113011CPR Heavy Duty 10M ‘1NC’1NC010M PRE-WIRED
113012CPR Heavy Duty QC M12 8way ‘1NC’1NC0250mm Leaded M12 8way
113013CPR Heavy Duty 2M ‘1NC 1NO’1NC1NO2M PRE-WIRED
113014CPR Heavy Duty 5M ‘1NC 1NO’1NC1NO5M PRE-WIRED
113015CPR Heavy Duty 10M ‘1NC 1NO’1NC1NO10M PRE-WIRED
113016CPR Heavy Duty QC M12 8way ‘1NC 1NO’1NC1NO250mm Leaded M12 8way

Technical Data
CertificatesTUV, cULus
Coding Level according to EN ISO 14119Low
TechnologyMagnetic
Housing MaterialRed, Polyester
Normally Closed ContactsUp to 2 N/C Safety (When the Guard is Closed)
Normally Open ContactsUp to 1 N/O Auxiliary (When the Guard is Closed)
Contact Release Time<2ms
Tolerance to Misalignment5mm in any Direction from 5mm Setting Gap
Connectivity2m, 5m, 10m, M12 QC
Length85mm
Width20.6mm
Height17mm
IP RatingIP67
Ambient Temperature-25 ... +80 °C
Storage Temperature-25 ... +80 °C
Switching Current, Minimum10V. Dc 1mA
Switching Voltage, Maximum (2NC)240V.ac / 24V.dc 1.0A. max. (Fuse externally 0.8A. (F).
Switching Voltage, Maximum (1NC)240V.ac / 24V.dc 2.0A. max. (Fuse externally 1.6A. (F).
Auxiliary Circuits (NO)24V.ac/dc 0.2A. max.
Switching Frequency1.0Hz max.
Approach Speed 200mm/m. to 1000mm/s.
CablePVC 6.0mm OD Conductors 0.25 sq.mm

Safety Classification and Reliability Data
ISO 13849-1Up to PLe Category 4 (if both channels are used with a PLe control device)
B10d3,300,000 cycles at 100mA load
Usage8 cycles/hour 24 hours/365 days per year MTTFd is 470 years