Leading Manufacturer of Safety Interlock Switches and Machine Guard Safety Switch Devices for Automation and Process Safety

Magnetic Non-Contact Safety Interlock Switch (RMR: M30)

HYGIEMAG are non-contact, magnetic safety switches designed for use on machinery and equipment to ensure the safety of the operators and prevent accidents. They are housed in a robust, 316 stainless steel and tested to IP69K, suitable for washdown applications.

  • Housing/Fixing: M30 Threaded Barrel
  • Contacts: Up to 2 N/C + 1 N/O
  • Sensing Distance: Wide 10mm operation
  • Connection: Pre-Wired or M12 8-Pole Quick Connect
  • Switching capability: 1A or (High Power 2A ac/dc)
PART NO.DESCRIPTIONSAFETYAUXILIARYCONNECTION
134009RMR 2M ‘2NC’2NC02M PRE-WIRED
134010RMR 5M ‘2NC’2NC05M PRE-WIRED
134011RMR 10M ‘2NC’2NC010M PRE-WIRED
134012RMR QC M12 8way ‘2NC’2NC0250mm Leaded M12 8way
134013RMR 2M ‘2NC 1NO’2NC1NO2M PRE-WIRED
134014RMR 5M ‘2NC 1NO’2NC1NO5M PRE-WIRED
134015RMR 10M ‘2NC 1NO’2NC1NO10M PRE-WIRED
134016RMR QC M12 8way ‘2NC 1NO’2NC1NO250mm Leaded M12 8way

Note
Suitable for Splash Zones in accordance with EHEDG guidelines.
Supplied with fixing nuts

Technical Data
CertificatesTUV, cULus
Coding Level according to EN ISO 14119Low
Housing Material316 Grade Stainless Steel
Normally Closed ContactsUp to 2 N/C Safety (When the Guard is Closed)
Normally Open ContactsUp to 1 N/O Auxiliary (When the Guard is Closed)
Contact Release Time<2ms
Tolerance to Misalignment5mm in any direction from 5mm setting gap
Connectivity2m, 5m, 10m, M12 QC
Length60mm
DiameterM30 x 1.5
IP RatingIP67, IP69K
Ambient Temperature-25 ... +105 °C
Storage Temperature -25 ... +105 °C
Switching Current, Minimum10V. Dc 1mA
Switching Voltage, Maximum (2NC)240V.ac / 24V.dc 1.0A. max. (Fuse externally 0.5A. (F).
Auxiliary Circuits (NO)24V.ac/dc 0.2A. max.
Switching Frequency1.0Hz max.
Approach Speed200mm/m. to 1000mm/s
CablePVC 6.0mm OD Conductors 0.25 sq.mm

Safety Classification and Reliability Data
ISO 13849-1Up to PLe Category 4 (if both channels are used with a PLe control device)
B10d3,300,000 cycles at 100mA load
Usage8 cycles/hour 24 hours/365 days per year MTTFd is 470 years