Leading Manufacturer of Safety Interlock Switches and Machine Guard Safety Switch Devices for Automation and Process Safety

Magnetic Non-Contact Safety Interlock Switch (BMR: M18)

HYGIEMAG are non-contact, magnetic safety switches designed for use on machinery and equipment to ensure the safety of the operators and prevent accidents. They are housed in a robust, 316 stainless steel and tested to IP69K, suitable for washdown applications.


  • Housing/Fixing: M18 Threaded Barrel
  • Contacts: Up to 2 N/C + 1 N/O
  • Sensing Distance: Wide 10mm operation
  • Connection: Pre-Wired or M12 8-Pole Quick Connect
  • Switching capability: 0.5A ac/dc
Part Number Part Description Safety Auxiliary Connection
416009 BMR 2M ‘2NC’ 2NC 0 2M PRE-WIRED
416010 BMR 5M ‘2NC’ 2NC 0 5M PRE-WIRED
416011 BMR 10M ‘2NC’ 2NC 0 10M PRE-WIRED
416012 BMR QC M12 8way ‘2NC’ 2NC 0 250mm Leaded M12 8way
416013 BMR 2M ‘2NC 1NO’ 2NC 1NO 2M PRE-WIRED
416014 BMR 5M ‘2NC 1NO’ 2NC 1NO 5M PRE-WIRED
416015 BMR 10M ‘2NC 1NO’ 2NC 1NO 10M PRE-WIRED
416016 BMR QC M12 8way ‘2NC 1NO’ 2NC 1NO 250mm Leaded M12 8way

Note
Suitable for Splash Zones in accordance with EHEDG guidelines.

Technical Data
CertificatesTUV, cULus
Coding Level according to EN ISO 14119Low
TechnologyMagnetic
Housing Material316 Grade Stainless Steel
Normally Closed ContactsUp to 2 N/C Safety
Normally Open ContactsUp to 1 N/O Auxiliary
Contact Release Time<2ms
Tolerance to Misalignment5mm in any direction from 5mm setting gap
Connectivity2m, 5m, 10m, M12 QC
Length75mm
DiameterM18 x 1
IP RatingIP67, IP69K
Ambient Temperature-25 ... +105 °C
Storage Temperature-25 ... +105 °C
Switching Current, Minimum10V. Dc 1mA
Switching Voltage, Maximum (2NC) 240V.ac / 24V.dc 1.0A. max. (Fuse externally 0.5A. (F).
Auxiliary Circuits (NO)24V.ac/dc 0.2A. max.
Switching Frequency1.0Hz max.
Approach Speed200mm/m. to 1000mm/s
CablePVC 6.0mm OD Conductors 0.25 sq.mm

Safety Classification and Reliability Data
ISO 13849-1Up to PLe Category 4 (if both channels are used with a PLe control device)
B10d3,300,000 cycles at 100mA load
Usage8 cycles/hour 24 hours/365 days per year MTTFd is 470 years