IDEM’s Magnetic Safety Switch Connection Accessories (140213 Connection Block)
- Connect up to 8 switches in series to one safety controller.
- Configured for dual circuit to a safety controller.
- 8 Auxiliary outputs for individual device status
- LED status of circuits
- Unused ports can be plugged.
- Screw clamp terminals.
- M20 Gland exit (supplied with cable gland).
NOTE: For use with IDEM’s magnetic non-contact safety switches only.
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Product Type | Part No. | Part Description |
|---|---|---|
| Connection Box | 140213 | 8 ports, 8-pin M12 sockets, 24 VDC LED indicator(s) |
| Patch Cord | 140201 | Patch Cord M12 Male to Female 2m |
| Patch Cord | 140202 | Patch Cord M12 Male to Female 5m |
| Patch Cord | 140203 | Patch Cord M12 Male to Female 10m |
| T-Port | 140208 | T-Port M12 Connector |
| Short Plug | 140209 | M12 Short Plug |
| Technical Data | |
|---|---|
| Port Connection Type | 8 x 8 Pin M12 Female sockets |
| Ambient Temperature | -20 ... +40 °C |
| Supply Voltage | 24V.dc (+/- 10%) |
| Maximum Current | 500mA |
| Body Material | Polyester |
| Internal Terminals | Screw type – clamp 16-30AWG conductors |
| Cable Exit | M20 cable gland |
| Mounting | 2 x M4 bolts (4.6mm dia. clearance holes) |
| Accessory | Shorting plug for unused ports |
| Information with regard to UL 508 | |
|---|---|
| Enclosure | Type 1 |
| Maximum Temperature | +40 °C |
| Maximum Current | 500mA |
| Terminals | 16-30AWG conductors |
| Terminal Torque | 6 lb-ins. (0.7Nm) |
| Powered by Class 2 or equivalent | |
| Polymeric conduit or gland connection only | |
| For use with IDEM (Non-Contact Magnetic switches only) |