Standalone Coded Non-Contact Safety Switch (PSA-D)
The PSA-D safety switch is a standalone, non-contact device with self-monitoring, force-guided mechanical contacts that maintains high functional safety levels even when connected in series, and it can be installed on guard doors without the need for additional safety monitoring equipment. It requires 2 actuators to operate, ideal for double door monitoring.
- Material: High Specification Polyester
- Safety Outputs: 2 (1 Force Guided)
- Ingress Protection: IP67
- Connection: Pre-Wired or M12 8 Pole Quick Connect (QC)
Note: Comes with two actuators
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Description | Safety Output 1 | Safety Output 2 | Auxiliary | Reset Mode | Connectivity |
|---|---|---|---|---|---|---|
| 117102 | PSA-D Plastic 5M with Dual Sensing | 1 (Force Guided Relay) | 1 | 1 | Automatic or Manual | 5M Pre-Wired |
| 117103 | PSA-D Plastic 10M with Dual Sensing | 1 (Force Guided Relay) | 1 | 1 | Automatic or Manual | 10M Pre-Wired |
| 117104 | PSA-D Plastic QC-M12 8way with Dual Sensing Automatic Start | 1 (Force Guided Relay) | 1 | 1 | Automatic | 250mm Pigtail M12-QC 8way |
| 117105 | PSA-D Plastic QC-M12 8way with Dual Sensing Manual Start | 1 (Force Guided Relay) | 1 | 1 | Manual | 250mm Pigtail M12-QC 8way |
| Technical Data | |
|---|---|
| Approvals | TUV, cULus |
| Coding Level according to EN ISO 14119 | Low |
| Technology | Coded Magnetic, Hall effect |
| Housing Material | Red, Polyester |
| Power Supply | 24Vdc +/-10% (Consumption 150mA max.) |
| NC Safety Output Max.Rating | 240Vac/24Vdc 3A* ac/dc (*Max. current for QC is 2A) |
| NO Auxiliary Output Max.Rating | 24Vdc 0.5A |
| Recommended Setting Gap | 5mm |
| Switching Distance | Sao 10mm Close / Sar 25mm Open |
| Tolerance to Misalignment | 5mm in any direction from 5mm setting gap |
| Approach Speed | 600mm/m to 1000mm/s |
| Temperature | -25 ... +45 °C |
| Cable | PVC 10 core 7mm OD |
| Characteristic Data according to IEC62061 (used as a sub system) | ||
|---|---|---|
| Safety Integrity Level | SIL3 | |
| PFH (1/h) | 3.95E-10 | Corresponds to 4.0% of SIL3 |
| PFD | 3.46E-05 | Corresponds to 3.5% of SIL3 |
| Proof Test Interval T1 | 20a |
| Characteristic Data according to EN ISO13849-1 | |
|---|---|
| Performance Level | e |
| Category | 4 |
| MTTFd | 446a |
| Diagnostic Coverage DC | 99% (high) |
| Information with regard to UL 508 | |
|---|---|
| Enclosure | Type 1 |
| NC Maximum Output | 24Vdc 3A |
| NO Maximum Output | 24V.dc 0.5A |
| Use Class 2 Supply or equivalent |