Coded Magnetic Non-Contact Safety Interlock Switch (LMC)

HYGIECODE range are magnetically coded, non-contact safety interlock switches for use on machinery and equipment to prevent accidents. The coding is achieved using a complex magnet arrangement and hall effect sensors, reducing the likelihood of manipulation or defeat.

  • Housed in a Narrow Design for Flush Mounting
  • Contacts up to 3 N/C or 2 N/C + 1 N/O
  • Wide 10mm Sensing Distance
  • Connectivity via Pre-Wired or M12 8-Pole Quick Connect
  • Indication via Single Colour LED – Green when Door is Closed
  • Switching capability up to 0.2A (Requires 24Vdc supply to operate)
  • Suitable for Splash Zones in Accordance with EHEDG Guidelines
Part No.Part Description
133001LMC 2M 2NC with LED
133002LMC 5M 2NC with LED
133003LMC 10M 2NC with LED
133004LMC QC M12 8way 2NC with LED
133005LMC 2M 2NC 1NO with LED
133006LMC 5M 2NC 1NO with LED
133007LMC 10M 2NC 1NO with LED
133007-10NLMC 10M 2NC 1NO with LED – 10N Magnetic holding
133008LMC QC M12 8way 2NC 1NO with LED
133017LMC 2M 3NC with LED
133018LMC 5M 3NC with LED
133019LMC 10M 3NC with LED
133020LMC QC M12 8way 3NC with LED
133021LMC 2M 2NC without LED
133022LMC 5M 2NC without LED
133023LMC 10M 2NC without LED
133024LMC QC M12 8way 2NC without LED
133025LMC 2M 2NC 1NO without LED
133026LMC 5M 2NC 1NO without LED
133027LMC 10M 2NC 1NO without LED
133028LMC QC M12 8way 2NC 1NO without LED
133111LMC 10M 1NC 1NO + aux with LED

Technical Data
ApprovalsTUV, cULus
Coding Level according to EN ISO 14119 Low
TechnologyCoded Magnetic, Hall effect
Housing Material316 Grade Stainless Steel
Normally Closed ContactsUp to 3 N/C Safety (When the Guard is Closed)
Normally Open ContactsUp to 1 N/O Auxiliary (When the Guard is Closed)
Switching DistanceSao 8mm / Sar 20mm
Response Time (OFF) 60ms Maximum
Tolerance to Misalignment5mm in any Direction from 5mm Setting Gap
IndicationGreen LED when Guard is Closed
Connectivity2m, 5m, 10m, M12 QC
Length 88mm
Width25mm
Height14mm
IP RatingIP67, IP69K
Ambient Temperature-25 ... +105 °C
Storage Temperature-25 ... +105 °C
Power Consumption25mA Max.
Maximum Switched Current (Outputs)200mA (Minimum Internal Resistance 8.5ohms)
Switching Frequency1.0 Hz Maximum
Approach Speed200mm/m. to 1000mm/s.
CablePVC 6mm O.D. Conductors 0.25 sq.mm

Safety Classification and Reliability Data
ISO 13849-1Up to PLe Category 4 (if both channels are used with a PLe control device)
PFHd2.6 x 10-10 (1/h)
Proof Test Interval (Life)20 years
MTTFd866 years

Information with regard to UL 508
Type 1 Enclosures. Maximum temperature: 50ºC plastic versions, 70ºC S/Steel versions. Maximum output 24V.dc 100mA. Powered by Class 2 or equivalent.