Coded Magnetic Non-Contact Safety Interlock Switch (CMC)
HYGIECODE range are magnetically coded, non-contact safety interlock switches for use on machinery and equipment to prevent accidents. The coding is achieved using a complex magnet arrangement and hall effect sensors, reducing the likelihood of manipulation or defeat.
- Industry Standard Housing and Mounting
- Contacts up to 3 N/C or 2 N/C + 1 N/O
- Wide 10mm Sensing operation
- Connectivity via Pre-Wired Cable or M12 8-Pole Quick Connect
- Indication via Single Colour LED – Green when door closed
- Switching capability up to 0.2A (Requires 24Vdc supply to operate)
- Suitable for Splash Zones in Accordance with EHEDG Guidelines
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part No. | Part Description |
|---|---|
| 138001 | CMC 2M 2NC with LED |
| 138002 | CMC 5M 2NC with LED |
| 138003 | CMC 10M 2NC with LED |
| 138004 | CMC QC M12 8way 2NC with LED |
| 138005 | CMC 2M 2NC 1NO with LED |
| 138006 | CMC 5M 2NC 1NO with LED |
| 138007 | CMC 10M 2NC 1NO with LED |
| 138008 | CMC QC M12 8way 2NC 1NO with LED |
| 138105 | CMC 2M 3NC with LED |
| 138106 | CMC 5M 3NC with LED |
| 138107 | CMC 10M 3NC with LED |
| 138108 | CMC QC M12 8way 3NC with LED |
| Technical Data | |
|---|---|
| Approvals | TUV, cULus |
| Coding Level according to EN ISO 14119 | Low |
| Technology | Coded Magnetic, Hall effect |
| Housing Material | 316 Grade Stainless Steel |
| Normally Closed Contacts | Up to 3 N/C Safety (When the Guard is Closed) |
| Normally Open Contacts | Up to 1 N/O Auxiliary (When the Guard is Closed) |
| Switching Distance | Sao 8mm / Sar 20mm |
| Response Time (OFF) | 60ms Maximum |
| Tolerance to Misalignment | 5mm in any Direction from 5mm Setting Gap |
| Indication | Green LED when Guard is Closed |
| Connectivity | 2m, 5m, 10m, M12 QC |
| Length | 85mm |
| Width | 20.6mm |
| Height | 17mm |
| IP Rating | IP67, IP69K |
| Ambient Temperature | -25 ... +105 °C |
| Storage Temperature | -25 ... +105 °C |
| Power Consumption | 25mA Max. |
| Maximum Switched Current (Outputs) | 200mA (Minimum Internal Resistance 8.5ohms) |
| Switching Frequency | 1.0 Hz Maximum |
| Approach Speed | 200mm/m. to 1000mm/s. |
| Cable | PVC 6mm O.D. Conductors 0.25 sq.mm |
| Safety Classification and Reliability Data | |
|---|---|
| ISO 13849-1 | Up to PLe Category 4 (if both channels are used with a PLe control device) |
| PFHd | 2.6 x 10-10 (1/h) |
| Proof Test Interval (Life) | 20 years |
| MTTFd | 866 years |
| Information with regard to UL 508 |
|---|
| Type 1 Enclosures. Maximum temperature: 50ºC plastic versions, 70ºC S/Steel versions. Maximum output 24V.dc 100mA. Powered by Class 2 or equivalent. |