Leading Manufacturer of Safety Interlock Switches and Machine Guard Safety Switch Devices for Automation and Process Safety

Coded Magnetic Non-Contact Safety Interlock Switch (CMC)

The Hygiecode range are magnetically coded, non-contact safety interlock switches have been developed for use on machinery and equipment to ensure the safety of the operators and prevent accidents.

  • Housing/Fixing: Industry Standard, Slim Line
  • Contacts: Up to 3 N/C or 2 N/C + 1 N/O
  • Sensing Distance: Wide 10mm operation
  • Connection: Pre-Wired or M12 8-Pole Quick Connect
  • Indication: Single Colour LED – Green when door closed
  • Switching capability: 0.2A (Requires 24Vdc supply to operate)

NOTE: Suitable for Splash Zones in accordance with EHEDG guidelines

Part No.Part Description
138001CMC 2M 2NC with LED
138002CMC 5M 2NC with LED
138003CMC 10M 2NC with LED
138004CMC QC M12 8way 2NC with LED
138005CMC 2M 2NC 1NO with LED
138006CMC 5M 2NC 1NO with LED
138007CMC 10M 2NC 1NO with LED
138008CMC QC M12 8way 2NC 1NO with LED
138105CMC 2M 3NC with LED
138106CMC 5M 3NC with LED
138107CMC 10M 3NC with LED
138108CMC QC M12 8way 3NC with LED

Technical Data
ApprovalsTUV, cULus
Coding Level according to EN ISO 14119Low
TechnologyCoded Magnetic, Hall effect
Housing Material316 Grade Stainless Steel
Normally Closed ContactsUp to 3 N/C Safety (When the Guard is Closed)
Normally Open ContactsUp to 1 N/O Auxiliary (When the Guard is Closed)
Switching DistanceSao 8mm / Sar 20mm
Response Time (OFF)60ms Maximum
Tolerance to Misalignment5mm in any Direction from 5mm Setting Gap
IndicationGreen LED when Guard is Closed
Connectivity2m, 5m, 10m, M12 QC
Length 85mm
Width20.6mm
Height17mm
IP RatingIP67, IP69K
Ambient Temperature-25 ... +105 °C
Storage Temperature-25 ... +105 °C
Power Consumption25mA Max.
Maximum Switched Current (Outputs)200mA (Minimum Internal Resistance 8.5ohms)
Switching Frequency 1.0 Hz Maximum
Approach Speed200mm/m. to 1000mm/s.
CablePVC 6mm O.D. Conductors 0.25 sq.mm

Safety Classification and Reliability Data
ISO 13849-1Up to PLe Category 4 (if both channels are used with a PLe control device)
PFHd 2.6 x 10-10 (1/h)
Proof Test Interval (Life)20 years
MTTFd866 years

Information with regard to UL 508
Type 1 Enclosures. Maximum temperature: 50ºC plastic versions, 70ºC S/Steel versions. Maximum output 24V.dc 100mA. Powered by Class 2 or equivalent.