Leading Manufacturer of Safety Interlock Switches and Machine Guard Safety Switch Devices for Automation and Process Safety

Coded Magnetic Non-Contact Safety Interlock Switch (SPC)

IDECODE Non-Contact safety interlock switches provide a reliable and convenient safety solution for industrial applications, featuring a solid-state design with high switching reliability, voltage-free safety outputs and magnetically coded actuator.


  • Housing/Fixing: Industry Standard, 22mm Fixing Holes
  • Contacts: Up to 3 N/C or 2 N/C + 1 N/O
  • Sensing Distance: 10mm operation
  • Connection: Pre-Wired or M12 8-Pole Quick Connect
  • Indication: Single Colour LED – Green when door closed
  • Switching capability: 0.2A (Requires 24Vdc supply to operate)

 

Part No. Part Description
111001 SPC 2M 2NC with LED
111002 SPC 5M 2NC with LED
111003 SPC 10M 2NC with LED
111004 SPC QC M12 8way 2NC with LED
111005 SPC 2M 2NC 1NO with LED
111006 SPC 5M 2NC 1NO with LED
111007 SPC 10M 2NC 1NO with LED
111008 SPC QC M12 8way 2NC 1NO with LED
111105 SPC 2M 3NC with LED
111106 SPC 5M 3NC with LED
111107 SPC 10M 3NC with LED
111108 SPC QC M12 8way 3NC with LED

Technical Data
ApprovalsTUV, cULus
Coding Level according to EN ISO 14119Low
TechnologyCoded Magnetic, Hall effect
Housing MaterialRed, Polyester
Normally Closed ContactsUp to 2 N/C Safety (When the Guard is Closed)
Normally Open ContactsUp to 1 N/O Auxiliary (When the Guard is Closed)
Switching DistanceSao 8mm / Sar 20mm
Response Time (OFF)60ms Maximum
Tolerance to Misalignment5mm in any Direction from 5mm Setting Gap
IndicationGreen LED when Guard is Closed
Connectivity2m, 5m, 10m, M12 QC
Length22.5mm
Width50mm
Height14mm
IP Rating IP67
Ambient Temperature -25 ... +80 °C
Storage Temperature -25 ... +80 °C
Power Consumption25mA Max.
Maximum Switched Current (Outputs)200mA (Minimum Internal Resistance 8.5ohms)
Switching Frequency1.0 Hz Maximum
Approach Speed 200mm/m. to 1000mm/s.
CablePVC 6mm O.D. Conductors 0.25 sq.mm

Safety Classification and Reliability Data
ISO 13849-1Up to PLe Category 4 (if both channels are used with a PLe control device)
PFHd2.6 x 10-10 (1/h)
Proof Test Interval (Life)20 years
MTTFd866 years

Information with regard to UL 508
Type 1 Enclosures. Maximum temperature: 50ºC plastic versions, 70ºC S/Steel versions. Maximum output 24V.dc 100mA. Powered by Class 2 or equivalent.