Leading Manufacturer of Safety Interlock Switches and Machine Guard Safety Switch Devices for Automation and Process Safety

Coded Magnetic Non-Contact Safety Interlock Switch (CPC)

IDECODE Non-Contact safety interlock switches provide a reliable and convenient safety solution for industrial applications, featuring a solid-state design with high switching reliability, voltage-free safety outputs and magnetically coded actuator.

  • Housing/Fixing: Industry Standard, Slim Line
  • Contacts: Up to 3 N/C or 2 N/C + 1 N/O
  • Sensing Distance: Wide 10mm operation
  • Connection: Pre-Wired or M12 8-Pole Quick Connect
  • Indication: Single Colour LED – Green when door closed
  • Switching capability: 0.2A (Requires 24Vdc supply to operate)

NOTE: LED located on the top of the switch

Part NumberDescriptionSafetyAuxiliarySupplyConnection
115001CPC 2NC 2M with LED2 NC024VDC2M PRE-WIRED
115002CPC 2NC 5M with LED2 NC024VDC5M PRE-WIRED
115003CPC 2NC 10M with LED2 NC024VDC10M PRE-WIRED
115004CPC 2NC QC-M12 8way with LED2 NC024VDC250MM PIGTAIL M12-QC 8-PIN
115005CPC 2NC 1NO 2M with LED2 NC1 NO24VDC2M PRE-WIRED
115006CPC 2NC 1NO 5M with LED2 NC1 NO24VDC5M PRE-WIRED
115007CPC 2NC 1NO 10M with LED2 NC1 NO24VDC10M PRE-WIRED
115008CPC 2NC 1NO QC-M12 8way with LED2 NC1 NO24VDC250MM PIGTAIL M12-QC 8-PIN

Technical Data
ApprovalsTUV, cULus
Coding Level according to EN ISO 14119Low
TechnologyCoded Magnetic, Hall effect
Housing MaterialRed, Polyester
Normally Closed ContactsUp to 2 N/C Safety (When the Guard is Closed)
Normally Open ContactsUp to 1 N/O Auxiliary (When the Guard is Closed)
Switching DistanceSao 8mm / Sar 20mm
Response Time (OFF)60ms Maximum
Tolerance to Misalignment5mm in any Direction from 5mm Setting Gap
IndicationGreen LED when Guard is Closed
Connectivity2m, 5m, 10m, M12 QC
Length85mm
Width20.6mm
Height17mm
IP RatingIP67
Ambient Temperature-25 ... +80 °C
Storage Temperature-25 ... +80 °C
Power Consumption25mA Max.
Maximum Switched Current (Outputs)200mA (Minimum Internal Resistance 8.5ohms)
Switching Frequency1.0 Hz Maximum
Approach Speed200mm/m. to 1000mm/s.
CablePVC 6mm O.D. Conductors 0.25 sq.mm

Safety Classification and Reliability Data
ISO 13849-1Up to PLe Category 4 (if both channels are used with a PLe control device)
PFHd2.6 x 10-10 (1/h)
Proof Test Interval (Life)20 years
MTTFd866 years

Information with regard to UL 508
Type 1 Enclosures. Maximum temperature: 50ºC plastic versions, 70ºC S/Steel versions. Maximum output 24V.dc 100mA. Powered by Class 2 or equivalent.