Coded Magnetic Non-Contact Safety Interlock Switch (LPC)

IDECODE Non-Contact safety interlock switches provide a reliable and convenient safety solution for industrial applications, featuring a solid-state design with high switching reliability, voltage-free safety outputs and magnetically coded actuator.


  • Housing/Fixing: Narrow design for flush mounting
  • Contacts: Up to 3 N/C or 2 N/C + 1 N/O
  • Sensing Distance: Wide 10mm operation
  • Connection: Pre-Wired or M12 8-Pole Quick Connect
  • Indication: Single Colour LED – Green when door closed
  • Switching capability: 0.2A (Requires 24Vdc supply to operate)
  • Magnetic (10N) holding versions available for use with small guards
Part No. Part Description
110001 LPC 2M ‘2NC’ with LED
110002 LPC 5M ‘2NC’ with LED
110002-10N LPC 5M ‘2NC’ with LED – 10N Holding
110003 LPC 10M ‘2NC’ with LED
110004 LPC QC M12 8way ‘2NC’ with LED
110005 LPC 2M ‘2NC 1NO’ with LED
110006 LPC 5M ‘2NC 1NO’ with LED
110007 LPC 10M ‘2NC 1NO’ with LED
110008 LPC QC M12 8way ‘2NC 1NO’ with LED
110031 LPC 2M ‘1NC 1NO’ with LED
110032 LPC 5M ‘1NC 1NO’ with LED
110033 LPC 10M ‘1NC 1NO’ with LED
110034 LPC QC M12 8way ‘1NC 1NO’ with LED
110070 LPC 2M ‘3NC’ with LED
110071 LPC 5M ‘3NC’ with LED
110072 LPC 10M ‘3NC’ with LED
110073 LPC QC M12 8way ‘3NC’ with LED

Technical Data
ApprovalsTUV, cULus
Coding Level according to EN ISO 14119Low
TechnologyCoded Magnetic, Hall effect
Housing MaterialRed, Polyester
Normally Closed ContactsUp to 2 N/C Safety (When the Guard is Closed)
Normally Open ContactsUp to 1 N/O Auxiliary (When the Guard is Closed)
Switching Distance Sao 8mm / Sar 20mm
Response Time (OFF)60ms Maximum
Tolerance to Misalignment5mm in any Direction from 5mm Setting Gap
IndicationGreen LED when Guard is Closed
Connectivity2m, 5m, 10m, M12 QC
Length88mm
Width25mm
Height14mm
IP RatingIP67
Ambient Temperature-25 ... +80 °C
Storage Temperature-25 ... +80 °C
Power Consumption25mA Max.
Maximum Switched Current (Outputs)200mA (Minimum Internal Resistance 8.5ohms)
Switching Frequency1.0 Hz Maximum
Approach Speed200mm/m. to 1000mm/s.
CablePVC 6mm O.D. Conductors 0.25 sq.mm

Safety Classification and Reliability Data
ISO 13849-1 Up to PLe Category 4 (if both channels are used with a PLe control device)
PFHd2.6 x 10-10 (1/h)
Proof Test Interval (Life)20 years
MTTFd866 years

Information with regard to UL 508
Type 1 Enclosures. Maximum temperature: 50ºC plastic versions, 70ºC S/Steel versions. Maximum output 24V.dc 100mA. Powered by Class 2 or equivalent.