Coded Magnetic Non-Contact Safety Switch KOBRACODE (KPC)
IDECODE Non-Contact safety interlock switches provide a reliable and convenient safety solution for industrial applications, featuring a solid-state design with high switching reliability, voltage-free safety outputs and magnetically coded actuator.
- Housing/Fixing: Industry Standard, Tongue Switch Body Style
- Contacts: Up to 2 N/C + 1 N/O
- Sensing Distance: 8mm Operation
- Connection: Pre-Wired or M12 8-Pole Quick Connect
- Indication: Single Colour LED – Green when door closed
- Switching capability: 0.2A (Requires 24Vdc supply to operate)
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Part Description | Safety | Auxiliary | Supply | Connection |
|---|---|---|---|---|---|
| 120001 | KPC 2NC 1NO 2M End with LED | 2 NC | 1 NO | 24VDC | 2M Pre-Wired (End Connection) |
| 120002 | KPC 2NC 1NO 5M End with LED | 2 NC | 1 NO | 24VDC | 5M Pre-Wired (End Connection) |
| 120003 | KPC 2NC 1NO 10M End with LED | 2 NC | 1 NO | 24VDC | 10M Pre-Wired (End Connection) |
| 120012 | KPC 2NC 1NO QC-M12 8way End with LED | 2 NC | 1 NO | 24VDC | 250MM Pigtail QC-M12 8way (End Connection) |
| 120004 | KPC 2NC 1NO 2M Left with LED | 2 NC | 1 NO | 24VDC | 2M Pre-Wired (Left Connection) |
| 120005 | KPC 2NC 1NO 5M Left with LED | 2 NC | 1 NO | 24VDC | 5M Pre-Wired (Left Connection) |
| 120006 | KPC 2NC 1NO 10M Left with LED | 2 NC | 1 NO | 24VDC | 10M Pre-Wired (Left Connection) |
| 120007 | KPC 2NC 1NO 2M Right with LED | 2 NC | 1 NO | 24VDC | 2M Pre-Wired (Right Connection) |
| 120008 | KPC 2NC 1NO 5M Right with LED | 2 NC | 1 NO | 24VDC | 5M Pre-Wired (Right Connection) |
| 120009 | KPC 2NC 1NO 10M Right with LED | 2 NC | 1 NO | 24VDC | 10M Pre-Wired (Right Connection) |
| Technical Data | |
|---|---|
| Approvals | TUV, cULus |
| Coding Level according to EN ISO 14119 | Low |
| Technology | Coded Magnetic, Hall effect |
| Housing Material | Red, Polyester |
| Normally Closed Contacts | Up to 2 N/C Safety (When the Guard is Closed) |
| Normally Open Contacts | Up to 1 N/O Auxiliary (When the Guard is Closed) |
| Switching Distance | Sao 8mm / Sar 20mm |
| Response Time (OFF) | 60ms Maximum |
| Tolerance to Misalignment | 5mm in any Direction from 5mm Setting Gap |
| Indication | Green LED when Guard is Closed |
| Connectivity | 2m, 5m, 10m, M12 QC |
| Length | 98mm |
| Width | 52mm |
| Height | 33.5mm |
| IP Rating | IP67 |
| Ambient Temperature | -25 ... +80 °C |
| Storage Temperature | -25 ... +80 °C |
| Power Consumption | 25mA Max. |
| Maximum Switched Current (Outputs) | 200mA (Minimum Internal Resistance 8.5ohms) |
| Switching Frequency | 1.0 Hz Maximum |
| Approach Speed | 200mm/m. to 1000mm/s. |
| Cable | PVC 6mm O.D. Conductors 0.25 sq.mm (End, Left or Right Entry) |
| Safety Classification and Reliability Data | |
|---|---|
| ISO 13849-1 | Up to PLe Category 4 (if both channels are used with a PLe control device) |
| PFHd | 2.6 x 10-10 (1/h) |
| Proof Test Interval (Life) | 20 years |
| MTTFd | 866 years |
| Information with regard to UL 508 |
|---|
| Type 1 Enclosures. Maximum temperature: 50ºC plastic versions, 70ºC S/Steel versions. Maximum output 24V.dc 100mA. Powered by Class 2 or equivalent. |