Left-Hand, 4 Control Stations, Die-Cast (UGB-NET-PS-M-LH)
UGB-NET safety interlock switch with integrated PROFINET PROFIsafe combines high-level RFID coding, guard locking, and machine control functions in a single heavy-duty housing, making it ideal for direct installation on access doors and hatches.
- Guard locking with monitoring and holding force up to 3000 N
- Highly coded RFID actuator for increased protection against tampering
- Four positions available for control devices
- Three connector plates providing flexible connection options (see technical drawings section)
- Integrated PROFIsafe safety switch
- Left-hand configuration (hinge on the left)
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Description | Manual Override | Connectivity |
|---|---|---|---|
| 528005 | UGB-NET-M-PS L. Hand | Yes | 3 connector plate options (see Technical Drawing tab) |
| 528007 | UGB-NET-M-PS L. Hand | No | 3 connector plate options (see Technical Drawing tab) |
| Safety functions |
|---|
| Guard interlocking Complies with the requirements of IEC 60947-5-3. Type 4 device with high coding acc. to ISO 14119. |
| Guard locking With lock monitoring for person and process protection. |
| Emergency stop. |
| Technical Data | |
|---|---|
| Certifications | CE, TUV, cULus |
| Actuator coding level | Type 4 (RFID), High (acc. to ISO 14119) |
| Assured sensing distance off (Sar) | 10 mm |
| Assured sensing distance on (Sao) | 20 mm |
| Assured locking distance | 5 mm |
| Response time (E Stop) | 36 ms max. (E-stop -> transmission to field bus) |
| Operating voltage | 24 V DC +10%/-15% (SELV/PELV) |
| Power Supply UL Requirements | Class 2 power supply must be used |
| Current consumption, max | 600 mA (Lock solenoid enabled) |
| Allowed through current (daisy-chain) | 5 A |
| Maximum holding force (F1) | 3000 N |
| Rated holding force (Fzh) | 2307 N |
| Body material | Die cast Aluminium |
| Head material | Stainless steel 316 |
| Environmental Data | -5 ... +50 °C |
| Enclosure Protection | IP 65 |
| Reliability / Safety Data (EN ISO 13849-1) | |
|---|---|
| Category | 4 |
| Performance Level | e |
| MTTFd | High |
| DC | 99% |
| Reliability / Safety Data (EN 62061 / IEC 61508) | |
|---|---|
| Mission Time | 20 years |
| SIL CL | SIL 3 |
| PFHd (Guard Interlocking / Lock Monitoring) | 7.3E-10 |
| PFHd (Emergency Stop Function) | 2.3E-9 |