Right-Hand, 4 Control Stations, Die-Cast (UGB-NET-CS-M-RH)
UGB-NET Gate Box with Integrated Ethernet/IP CIP Safety combines high level RFID coded interlocking and machine control functions in one heavy duty housing. The compact design is less than 250mm long (10 inches) and 115mm (4.5 inches), suitable for integration onto access doors and hatches.
- Guard Locking with monitoring up to 3000N
- RFID coded actuator
- Four positions for 22mm pilot devices
- Connection via plug connector M12, D-Coded
- Power via M12, A-Coded
- Integrated CIP Safety switch
- Right-hand configuration (hinge on the right)
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Description | Manual Override | Rear Release | Orientation |
|---|---|---|---|---|
| 528101 | UGB-NET-CS-M | Yes | No | Right-Hand |
| 528103 | UGB-NET-CS-M | No | No | Right-Hand |
| Safety functions |
|---|
| Guard interlocking Complies with the requirements of IEC 60947-5-3. Type 4 device with high coding acc. to ISO 14119. |
| Guard locking With lock monitoring for person and process protection. |
| Emergency stop. |
| Technical Data | |
|---|---|
| Certifications | CE, TUV, cULus |
| Actuator coding level | Type 4 (RFID), High (acc. to ISO 14119) |
| Assured sensing distance on (Sao) | 10 mm |
| Assured sensing distance off (Sar) | 20 mm |
| Assured locking distance | 5 mm |
| Response time (E Stop) | 36 ms max. (E-stop -> transmission to field bus) |
| Operating voltage | 24 V DC +10%/-15% (SELV/PELV) |
| Power Supply UL Requirements | Class 2 power supply must be used |
| Current consumption, max | 600 mA (Lock solenoid enabled) |
| Allowed through current (daisy-chain) | 5 A |
| Maximum holding force (F1) | 3000 N |
| Rated holding force (Fzh) | 2307 N |
| Body material | Die cast Aluminium |
| Head material | Stainless steel 316 |
| Environmental Data | -5 ... +50 °C |
| Enclosure Protection | IP 65 |
| Reliability / Safety Data (EN ISO 13849-1) | |
|---|---|
| Category | 4 |
| Performance Level | e |
| MTTFd | High |
| DC | 99% |
| Reliability / Safety Data (EN 62061 / IEC 61508) | |
|---|---|
| Mission Time | 20 years |
| SIL CL | SIL 3 |
| PFHd (Guard Interlocking / Lock Monitoring) | 7.3E-10 |