Hinge Door Safety Interlock Switch (HSM)
IDEM’s HSM Die Cast Hinge Switch with a mirror polished finish has been designed to be mounted for interlock position sensing of hinged moving guards. Once fitted to the hinged axis of the machine guard door, they provide a robust hinge function in addition to interlock position sensing.
- Housing: Die-Cast, Mirror Finish
- Axial Holding Force: 800N
- Contacts: 3NC 1NO, or 2NC 2NO
- Ingress Protection: IP67
- Activation Type: Left- or Right-Hand Versions Available
- Mounting is achieved by fixing the switch from behind. If you do not have access to the back of the switch, a separate mounting bracket accessory can be purchased for front fixing.
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part No. | Part Description |
|---|---|
| 351001 | HSM Right 5m 3NC 1NO |
| 351002 | HSM Right 10m 3NC 1NO |
| 351003 | HSM Right QC-M12 3NC 1NO |
| 351004 | HSM Right 5m 2NC 2NO |
| 351005 | HSM Right 10m 2NC 2NO |
| 351006 | HSM Right QC-M12 2NC 2NO |
| 351007 | HSM Left 5m 3NC 1NO |
| 351008 | HSM Left 10m 3NC 1NO |
| 351009 | HSM Left QC-M12 3NC 1NO |
| 351010 | HSM Left 5m 2NC 2NO |
| 351011 | HSM Left 10m 2NC 2NO |
| 351012 | HSM Left QC-M12 2NC 2NO |
| Technical Data | |
|---|---|
| Approvals | cULus |
| Technology | Hinge cam |
| Housing Material | Die-Cast Metal (Black Plated Mirror Finish) |
| Contact Configuration | 3 N/C + 1 N/O, or 2 N/C + 2 N/O |
| Utilization Category | AC15 A300 3A |
| Thermal Current (lth) | 10A |
| Overload protection fuse (fuse externally) | 10A. (FF) |
| Rated Insulation/Withstand Voltages | 600VAC/2500VAC |
| Actuator Rotation for Positive Opening | 6 degrees 0.5Nm (Type Zb contacts) |
| Maximum Approach Withdrawal Speed | 600mm/s |
| Enclosure Protection | IP67 |
| Operating Temperature | -25 ... +80 °C |
| Vibration | IEC 68-2-6 10-55Hz+1Hz Excursion: 0.35mm, 1 octave/min |
| Fixing | 7 x M5 |
| Tightening Torque (all mounting bolts) | 4Nm |
| Mounting Position | Any |
| Pollution Degree | 3 |
| Short Circuit Overload Protection | Fuse externally 10A (FF) |
| Altitude | Max. Altitude 2000m |
| Humidity | Relative Humidity 90% at 20 ºC (Non-Condensing) |
| Safety Classification & Reliability Data | |
|---|---|
| Mechanical Reliability B10d | 1.5 x 10 6 operations at 100mA load |
| ISO 13849-1 | Up to PLe depending upon system architecture |
| EN62061 | Up to SIL3 depending upon system architecture |
| Safety Data – Annual Usage | 8 cycles per hour/24 hours per day/365 days MTTFd 356 years |
| Information with regards to UL standards |
|---|
| Electrical Rating: Pilot Duty 30VAC, 45VA-450VA make / 45 VA break; 2.5A thermal 36VDC, 55VA make / break Maximum ambient temperature 50ºC (Connector versions: 30V. AC/DC 2A. Max.) |