Hinge Interlock Safety Switch (IDIS-2)
IDIS-2 Switches are designed to be mounted for interlock position sensing of hinged moving guards. They are easily fitted to the hinged axis of machine guard doors and offers a high degree of anti-tamper.
- Material: Polyester body and Stainless-Steel Lever
- Fixing: 22mm Mounting Holes
- Contacts: 2 N/C + 1 N/O or 3NC
- Connection: M20, ½” NPT or M12 QC
- Universal fitting – opening angle 180 degrees for swing doors.
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part No. | Part Description |
|---|---|
| 192001 | IDIS-2 M20 2NC 1NO |
| 192002 | IDIS-2 ½NPT 2NC 1NO |
| 192003 | IDIS-2 QC ½UNF 6way 2NC 1NO |
| 192004 | IDIS-2 M20 3NC |
| 192005 | IDIS-2 ½NPT 3NC |
| 192006 | IDIS-2 QC ½UNF 6way 3NC |
| 192007 | IDIS-2 M20 1NC 1NO Snap |
| 192008 | IDIS-2 ½NPT 1NC 1NO Snap |
| 192009 | IDIS-2 QC ½UNF 6way 1NC 1NO Snap |
| 192022 | IDIS-2 QC M12 8way 2NC 1NO |
| 192023 | IDIS-2 QC M12 8way 3NC |
| 192024 | IDIS-2 QC M12 8way 1NC 1NO Snap |
| Technical Data | |
|---|---|
| Approvals | cULus |
| Technology | Hinge Lever |
| Housing Material | Red Polyester |
| Contact Configuration | 2 N/C + 1 N/O, 3 N/C or 1 N/C + 1 N/O Snap |
| Utilization Category | AC15 A300 3A |
| Thermal Current (lth) | 10A |
| Overload protection fuse (fuse externally) | 10A. (FF) |
| Rated Insulation/Withstand Voltages | 600VAC/2500VAC |
| Actuator Rotation for Positive Opening | 7 degrees 0.5Nm |
| Enclosure Protection | IP67 |
| Operating Temperature | -25 ... +80 °C |
| Vibration | IEC 68-2-6 10-55Hz+1Hz Excursion: 0.35mm, 1 octave/min |
| Conduit Entry | 1/2" UNF, 1/2" NPT and M20 |
| Fixing | 2 x M4 |
| Safety Classification & Reliability Data | |
|---|---|
| Mechanical Reliability B10d | 2.5 x 106 operations at 100mA load |
| ISO 13849-1 | Up to PLe depending upon system architecture |
| EN62061 | Up to SIL3 depending upon system architecture |
| Safety Data – Annual Usage | 8 cycles per hour/24 hours per day/365 days MTTFd 356 years |
| Information with regard to UL Standards |
|---|
| Type 1 Enclosures. Use 16 - 12AWG stranded copper insulated conductors rated 90ºC minimum. (75C. ampacity). Terminal tightening torque 7ibs ins (0.8Nm). Intended for same polarity use and one polymeric conduit connection. Not suitable for connection to a rigid metal conduit system. Electrical Rating: Pilot Duty A300 240V.ac 3A. 6,000 cycles. Maximum ambient temperature 40ºC. |