Hinge Interlock Safety Switch (HC-SS)
Hingecam Switches are designed to be mounted for interlock position sensing of hinged moving guards. They are easily fitted to the hinged axis of machine guard doors and offers a high degree of anti-tamper. The HC-SS is manufactured from 316 stainless steel suitable for washdown environments.
- Material: Mirror Polished 316 Stainless Steel
- Connection: M20, ½” NPT or M12 QC
- Contacts: 2 N/C Safety and 1 N/C Auxiliary
- Operating Temp: -25C to +80C
- Hollow Shafts Available
- Solid shafts are available as: 10mm dia. and 50 or 80mm long or as 8mm dia. and 60mm long.
- Actuator rotation for positive opening – 7 degrees 0.5Nm
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part No. | Part Description |
|---|---|
| 195001 | HC-SS M20 2NC 1NO (shaft dia 10mmx80mm) |
| 195002 | HC-SS 1/2NPT 2NC 1NO (shaft dia 10mmx80mm) |
| 195003 | HC-SS QC M12 8way 2NC 1NO (shaft dia 10mmx80mm) |
| 195004 | HC-SS M20 2NC 1NO (shaft dia 10mmx50mm) |
| 195005 | HC-SS 1/2NPT 2NC 1NO (shaft dia 10mmx50mm) |
| 195006 | HC-SS QC M12 8way 2NC 1NO (shaft dia 10mmx50mm) |
| 195007 | HC-SS M20 2NC 1NO (shaft dia 8mmx60mm) |
| 195008 | HC-SS 1/2NPT 2NC 1NO (shaft dia 8mmx60mm) |
| 195009 | HC-SS QC M12 8way 2NC 1NO (shaft dia 8mmx60mm) |
| 195010 | HC-SS M20 2NC 1NO (shaft hollow dia 16mmx30mm) |
| 195011 | HC-SS 1/2NPT 2NC 1NO (shaft hollow dia 16mmx30mm) |
| 195012 | HC-SS QC M12 8way 2NC 1NO (shaft hollow dia 16mmx30mm) |
| Technical Data | |
|---|---|
| Approvals | cULus |
| Technology | Hinge Cam |
| Housing Material | 316 Grade Stainless Steel |
| Contact Configuration | 2 N/C + 1 N/O |
| Utilization Category | AC15 A300 3A |
| Thermal Current (lth) | 10A |
| Overload protection fuse (fuse externally) | 10A. (FF) |
| Rated Insulation/Withstand Voltages | 600VAC/2500VAC |
| Actuator Rotation for Positive Opening | 7 degrees 0.5Nm (Type Zb contacts) |
| Actuator Entry Minimum Radius | 175mm Standard 100mm Flexible |
| Maximum Approach Withdrawal Speed | 600mm/s |
| Enclosure Protection | IP67, IP69K (QC version IP67 at the connector) |
| Operating Temperature | -25 ... +80 °C |
| Vibration | IEC 68-2-6 10-55Hz+1Hz Excursion: 0.35mm, 1 octave/min |
| Conduit Entry | M20 or 1/2" NPT |
| Fixing | 2 x M4 |
| Pollution Degree | 3 |
| Short Circuit Overload Protection | Fuse externally 10A (FF) |
| Safety Classification & Reliability Data | |
|---|---|
| Mechanical Reliability B10d | 2.5 x 106 operations at 100mA load |
| ISO 13849-1 | Up to PLe depending upon system architecture |
| EN62061 | Up to SIL3 depending upon system architecture |
| Safety Data – Annual Usage | 8 cycles per hour/24 hours per day/365 days MTTFd 356 years |
| Information with regard to UL Standards |
|---|
| Type 1 Enclosures. Use 16 - 12AWG stranded copper insulated conductors rated 90ºC minimum. (75C. ampacity). Terminal tightening torque 7ibs ins (0.8Nm). Intended for same polarity use and one polymeric conduit connection. Not suitable for connection to a rigid metal conduit system. Electrical Rating: Pilot Duty A300 240V. 3A. 6,000 cycles. Maximum ambient temperature 80ºC. HC-SS (Earth bonding terminal inside enclosure if required). |


