Safety Rope Pull Switch for Hazardous Areas (GLS-Ex)
The GLS-EX standard duty safety rope pull switch has been designed to protect medium to long conveyor lengths, where protection is required up to 100m (using 2 switches) or up to 80m (using 1 switch).
- Body Material: Die-Cast Metal; Painted Yellow
- Ingress Protection: IP67
- Contacts: 2-Pole or 4-Pole Ex Rated Contact Blocks
- Cable Length (1 Switch): 80m
- Cable Length (2 Switches): 100m
- Zones: 1, 21, 2, 22
- Ex Marking: Exd IIC T6 (-20 ≤ Ta ≤ +60C) Gb / Ex tb IIIC T85C (-20 ≤ Ta ≤ +60C) Db
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Part Description |
|---|---|
| 142025 | GLS-Ex 3M ‘1NC 1NO’c/w E-Stop |
| 142025-10M | GLS-Ex **10M** ‘1NC 1NO’c/w E-Stop |
| 142025-15M | GLS-Ex **15M** ‘1NC 1NO’c/w E-Stop |
| 142025-20M | GLS-Ex **20M** ‘1NC 1NO’c/w E-Stop |
| 142028 | GLS-Ex 3M ‘2NC’c/w E-Stop |
| 142030 | GLS-Ex 3M ‘2NC 2NO’c/w E-Stop |
| 142030-15M | GLS-Ex **15M** ‘2NC 2NO’c/w E-Stop |
| Important Note |
|---|
| Comes with 3m of pre-wired cable (longer available on request). |
| Technical Data | |
|---|---|
| Approvals | IECEx, cULus on LS-Ex Internal Contact Block |
| Technology | Safety Rope Pull Switch |
| Housing Material | Painted Die-Cast Aluminum |
| Operating Temperature | -25 ... +80 °C |
| Enclosure Protection | IP67 |
| Rope Spans | Up to 100m |
| Rope Type | 4.0mm Outside Dia. Steel inner-PVC sheath |
| Switching frequency (LS-Ex) | 1.0 Hz maximum |
| Mechanical Life Expectancy (LS-Ex) | 1,000,000 switches |
| Electrical Life Expectancy (LS-Ex) | Tested to 1,000,000 cycles at 24V. 0.2A |
| Ex Classification |
|---|
| ATEX Zones 1,21,2,22 |
| II 2G Ex mb IIC T6 Gb |
| II 2D Ex mb IIIC T80C Db |