RFID Safety Gate Box 4 Station with Rear Release (UGB4-KLT-SS-RFID-RR)
UGB-KLT-SS-RFID provides high level RFID coded interlocking and machine control functions in one heavy duty housing. They can be easily fitted to access doors to provide guard locking, rear escape options and sliding or rotary handles to reduce the risk of operators being trapped inside a guarded area. The UGB-KLT-SS-RFID housing will incorporate 22mm push buttons, lamps or switches which can be added to provide machine request or control functions in one form factor.
- Body Material: Mirror Polished 316 Grade Stainless Steel
- Ingress Protection: IP65
- RFID Coding: Unique (can be retaught if lost or damaged)
- Control Devices: 4
- Connection: 3 x M20 or ½” NPT (Quick Connect Options Available)
NOTE: Pilot devices, handle accessories sold separately.
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Description | Safety Channels | Auxiliary | Rear Release | Manual Override | Conduit |
|---|---|---|---|---|---|---|
| 521002 | UGB4-KLT-SS-RFID-RR Manual Override | 2NC Lock / 2NC Guard | 1 PNP Lock / 1 PNP Guard | Yes | Yes | M20 |
| 521004 | UGB4-KLT-SS-RFID-RR No Manual Override | 2NC Lock / 2NC Guard | 1 PNP Lock / 1 PNP Guard | yes | No | M20 |
| Technical Data | |
|---|---|
| Approvals | TUV, cULus |
| Classification and Coding Level according to EN ISO 14119 | Type 4, High |
| Technology | RFID, Power to Unlock |
| Housing Material | 316 Grade Stainless Steel |
| Supply Voltage | 24Vdc (+/- 10%) |
| Power Consumption | R+ 1.2W (50mA Max.) / S+ 12W (500mA Max.) |
| Safety Circuits | 24Vdc 200mA max. switching |
| Auxiliary Circuits (34 & 44) | 24Vdc 200mA max. Output feed |
| Rated Insulation Voltage | 500VAC |
| Rated Impulse withstand | 1000VAC |
| Holding Force | F1Max 3000N Fzh 2307N |
| Assured locking distance | 5mm |
| Sao (RFID) | 10mm |
| Sar (RFID) | 20mm |
| Max operating frequency | 1Hz |
| Actuator entry minimum radius | 175mm |
| Enclosure Protection | IP65 |
| Operating Temperature | -25 ... +40 °C |
| Mechanical Life Expectancy (B10d) | 2.5 x 10 6 cycles at 100mA load |
| Vibration | IEC68-2-6, 10-55Hz+1Hz Excursion: 0.35mm, 1 octave/min |
| Characteristic data according to IEC62021 (used as a subsystem) | |
|---|---|
| Safety Integrity Level | SIL 3 |
| PFH (1/h) | 4.77E-10 (Corresponds to 4.8% of SIL3) |
| PFD | 4.18E-05 (Corresponds to 4.2% of SIL3) |
| Proof Test Interval T1 | 20a |
| Characteristic data according to EN ISO13849-1 | |
|---|---|
| Performance Level | e (If both channels are used in conjunction with a SIL 3 / PL e control device) |
| Diagnostic Coverage DC | 99% (High) (If both channels are used in conjunction with a SIL 3 / PL e control device) |
| Category | Cat 4 |
| MTTFd | 1100a |
| Information with regard to UL 508 |
|---|
| Type 1 enclosure. Maximum temperature 40°C. Use 16-28AWG copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7Nm). Intended for same polarity use. Safety Circuits (11-31 & 21-41) A300 Pilot Duty. 240V. 3A. (PF 0.38 or greater tested for 6,000 cycles endurance). Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit. (Earth bonding terminal inside enclosure if required – use 16-12AWG conductors). Push Button ratings (Optional) 120 -240 Vac, 1.5 - 1.0 A 24 - 125 Vdc, 0.3 – 0.2 A |