Emergency Stop Device 4-Pole Contacts in 316 Stainless Steel (ESL-SS)
IDEM’s Heavy Duty Emergency Stop Switches are designed to provide robust Emergency Stop protection for exposed conveyors or machines. The IP69K enclosure protection is maintained by a double seal gasket and anti-rust, stainless steel internal screws.
- Body Material: Rugged 316 Grade Stainless Steel
- Ingress Protection: IP69K
- Contacts: 4NC, 3NC + 1NO or 2NC + 2NO
- Conduits: 3 x M20 or ½” NPT
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Part Description | Connection Type | Contacts | Gold Contacts |
|---|---|---|---|---|
| 232001 | ESL-SS M20 2NC 2NO | M20 | 2NC 2NO | No |
| 232002 | ESL-SS ½”NPT 2NC 2NO | ½”NPT | 2NC 2NO | No |
| 232002-GC | ESL-SS ½”NPT 2NC 2NO with Gold Contacts | ½”NPT | 2NC 2NO | Yes |
| 232003 | ESL-SS M20 3NC 1NO | M20 | 3NC 1NO | No |
| 232003-GC | ESL-SS M20 3NC 1NO with Gold Contacts | M20 | 3NC 1NO | Yes |
| 232004 | ESL-SS ½”NPT 3NC 1NO | ½”NPT | 3NC 1NO | No |
| 232005 | ESL-SS M20 4NC | M20 | 4NC | No |
| 232006 | ESL-SS ½”NPT 4NC | ½”NPT | 4NC | No |
| Important Note |
|---|
| When required by local regulations, please affix the supplied yellow emergency stop sticker. |
| Technical Data | |
|---|---|
| Approvals | cULus |
| Technology | Emergency Stop, Twist-To-Release |
| Housing Material | 316 Grade Stainless Steel |
| Button Material | UV Resistant Polyester |
| Safety Contact type | IEC 60947-5-1 Double break Type Zb |
| Termination | Clamp up to 2.5 sq. mm conductors |
| Rating | Utilisation Category : AC15 |
| Operational Rating | AC15 A300 240V. 3A /120V 6A. ac |
| Thermal Current (Ith) | 10A. |
| Rated Insulation Voltage (Ui) | 500V |
| Withstand Voltage (Uimp) | 2500V. |
| Short Circuit Overload Protection | Fuse Externally 10A. (FF) |
| Operating Temperature | -25 ... +80 °C |
| Enclosure Protection | IP67, IP69K (NEMA 6) |
| Safety Classification and Reliability Data | |
|---|---|
| Mechanical Reliability B10d | 1.5 x 10 6 operations at 100mA load |
| ISO 13849-1 | up to PLe depending upon system architecture |
| EN 62061 | up to SIL3 depending upon system architecture |
| Safety Data - Annual Usage | 8 cycles per hour / 24 hours per day / 365 days MTTFd 214 years |
| INFORMATION WITH REGARD TO UL508 |
|---|
| Type 1 Enclosure Contact Blocks A300 230V/3A 120V/6A Wire range: 16AWG – 12AWG Stranded Copper Conductors Terminal Torque 7lb/in (0.8Nm) 24V LED (if fitted) powered by LVLC or Class 2 only. |