Hygienic Emergency Stop Device with 4-Pole Contacts (ESL-SS-WR)
The ESL-SS-WR has been developed for use in food contact zones, providing reliable protection in food, beverage, and pharmaceutical applications. Its innovative design includes a single-piece lid enclosure with sloped edges that make it easy to clean and minimize the risk of liquids lingering on the surface after cleaning. The Ra10 mirror-polished surface is able to withstand the rigorous cleaning procedures that are standard in food manufacturing. Additionally, the ESL-SS-WR has a unique button design which is made of X-ray and metal detectable material.
- Body Material: Mirror Polished 316 Grade Stainless Steel
- Ingress Protection: IP69K
- Contacts: 4NC, 3NC + 1NO or 2NC + 2NO
- Conduits: M20 or ½” NPT
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part No. | Part Description |
|---|---|
| 239001 | ESL-SS-WR M20 ‘2NC 2NO’ |
| 239002 | ESL-SS-WR 1/2″ NPT ‘2NC 2NO’ |
| 239003 | ESL-SS-WR M20 ‘3NC 1NO’ |
| 239004 | ESL-SS-WR 1/2″ NPT ‘3NC 1NO’ |
| 239005 | ESL-SS-WR M20 ‘4NC’ |
| 239006 | ESL-SS-WR 1/2″ NPT ‘4NC’ |
| 239300 | Rear Rubber Seal |
| 239301 | Stainless Steel Spacer Kit |
| Technical Data | |
|---|---|
| Approvals | cULus |
| Technology | Emergency Stop, Twist-To-Release |
| Housing Material | 316 Grade Stainless Steel |
| Button Material | UV Resistant, X-Ray and Metal Detectable Polyester |
| Safety Contact type | IEC 60947-5-1 Double break Type Zb |
| Termination | Clamp up to 2.5 sq. mm conductors |
| Rating | Utilisation Category : AC15 |
| Operational Rating | AC15 A300 240V. 3A /120V 6A. ac |
| Thermal Current (Ith) | 10A |
| Rated Insulation Voltage (Ui) | 500V |
| Withstand Voltage (Uimp) | 2500V. |
| Short Circuit Overload Protection | Fuse Externally 10A. (FF) |
| Operating Temperature | -25 ... +80 °C |
| Enclosure Protection | IP67, IP69K (NEMA 6) |
| Safety Classification and Reliability Data | |
|---|---|
| Mechanical Reliability B10d | 1.5 x 10 6 operations at 100mA load |
| ISO 13849-1 | up to PLe depending upon system architecture |
| EN 62061 | up to SIL3 depending upon system architecture |
| Safety Data - Annual Usage | 8 cycles per hour / 24 hours per day / 365 days MTTFd 214 years |
| INFORMATION WITH REGARD TO UL508 |
|---|
| Type 1 Enclosure Contact Blocks A300 230V/3A 120V/6A Wire range: 16AWG – 12AWG Stranded Copper Conductors Terminal Torque 7lb/in (0.8Nm) 24V LED (if fitted) powered by LVLC or Class 2 only. |