Emergency Stop Device with 3-Pole Contacts (ES-P)
The ES-P emergency stop button is used to immediately halt hazardous processes or machinery in order to prevent or minimize injury to personnel or damage to equipment. IDEM’s Standard Duty Emergency Stop Switches are designed to provide robust Emergency Stop protection for exposed conveyors or machines.
Conformance to ISO13850, IEC60947-5-1 and IEC60947-5-5.
Designed with a special lid safety trip mechanism means that the safety contacts will open if the lid is removed from the Emergency Stop Switch adding an extra level of protection.
- Body Material: High Specification Polyester in Yellow
- Ingress Protection: IP67
- Contacts: 3NC or 2NC + 1NO
- Conduits: 2 x M20 or ½” NPT Knockout
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Part Description | Contact Configuration | Conduit |
|---|---|---|---|
| 230001 | ES-P Knockout M20 ½NPT 2NC 1NO | 2 N/C + 1 N/O | M20 1/2" NPT Knockout |
| 230002 | ES-P Knockout M20 ½NPT 3NC | 3 N/C | M20 1/2" NPT Knockout |
| Technical Data | |
|---|---|
| Approvals | cULus |
| Technology | Emergency Stop, Twist-To-Release |
| Housing Material | Yellow Polyester |
| Button Material | UV Resistant Polyester |
| Safety Contact type | IEC 60947-5-1 Double break Type Zb |
| Termination | Clamp up to 2.5 sq. mm conductors |
| Rating | Utilisation Category : AC15 |
| Operational Rating | AC15 A300 240V. 3A /120V 6A. ac |
| Thermal Current (Ith) | 10A. |
| Rated Insulation Voltage (Ui) | 500V |
| Withstand Voltage (Uimp) | 2500V. |
| Short Circuit Overload Protection | Fuse Externally 10A. (FF) |
| Operating Temperature | -25 ... +80 °C |
| Enclosure Protection | IP67 |
| Safety Classification and Reliability Data | |
|---|---|
| Mechanical Reliability B10d | 1.5 x 10 6 operations at 100mA load |
| ISO 13849-1 | up to PLe depending upon system architecture |
| EN 62061 | up to SIL3 depending upon system architecture |
| Safety Data - Annual Usage | 8 cycles per hour / 24 hours per day / 365 days MTTFd 214 years |
| INFORMATION WITH REGARD TO UL508 |
|---|
| Type 1 Enclosure Contact Blocks A300 230V/3A 120V/6A Wire range: 16AWG – 12AWG Stranded Copper Conductors Terminal Torque 7lb/in (0.8Nm) 24V LED (if fitted) powered by LVLC or Class 2 only. |