Emergency Stop Device with LED and QC-M12 (ES-P-L)
The ES-P-L emergency stop button provides immediate shutdown of hazardous machinery or processes to help prevent injury and equipment damage. Designed for standard-duty applications, IDEM’s ES-P-L offers reliable safety protection for exposed conveyors or machines.
It features an integrated LED indicator on the lid for clear status visibility and includes a unique lid safety trip mechanism—if the lid is removed, the safety contacts automatically open, adding an extra layer of protection.
The ES-P-L complies with ISO 13850, IEC 60947-5-1, and IEC 60947-5-5 standards, ensuring reliable performance in industrial environments.
- Body Material: High Specification Polyester in Yellow
- Ingress Protection: IP67
- Contacts: 2NC + (1NO for LED)
- Connectivity: 8-Way M12 Connector (Left- or Right-Hand Exit)
- Indication: Bi-Colour LED
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Part Description | Contact Configuration | Conduit |
|---|---|---|---|
| 230005 | ES-P (L) 2NC with LED M12 8 Pin LH Connector Exit | 2 N/C | 8-Way QC-M12 Left-Hand Exit |
| 230006 | ES-P (L) 2NC with LED M12 8 Pin RH Connector Exit | 2 N/C | 8-Way QC-M12 Right-Hand Exit |
| Technical Data | |
|---|---|
| Approvals | cULus |
| Technology | Emergency Stop, Twist-To-Release |
| Housing Material | Yellow Polyester |
| Button Material | UV Resistant Polyester |
| Safety Contact type | IEC 60947-5-1 Double break Type Zb |
| Termination | Clamp up to 2.5 sq. mm conductors |
| Rating | Utilisation Category : AC15 |
| Operational Rating | AC15 A300 240V. 3A /120V 6A. ac |
| Thermal Current (Ith) | 10A. |
| Rated Insulation Voltage (Ui) | 500V |
| Withstand Voltage (Uimp) | 2500V. |
| Short Circuit Overload Protection | Fuse Externally 10A. (FF) |
| Operating Temperature | -25 ... +80 °C |
| Enclosure Protection | IP67 |
| Safety Classification and Reliability Data | |
|---|---|
| Mechanical Reliability B10d | 1.5 x 10 6 operations at 100mA load |
| ISO 13849-1 | up to PLe depending upon system architecture |
| EN 62061 | up to SIL3 depending upon system architecture |
| Safety Data - Annual Usage | 8 cycles per hour / 24 hours per day / 365 days MTTFd 214 years |
| INFORMATION WITH REGARD TO UL508 |
|---|
| Type 1 Enclosure Contact Blocks A300 230V/3A 120V/6A Wire range: 16AWG – 12AWG Stranded Copper Conductors Terminal Torque 7lb/in (0.8Nm) 24V LED (if fitted) powered by LVLC or Class 2 only. |