Electromagnetic RFID Safety Switch 1000N (MGL-3P)

The MGL-3P is a magnetic guard locking safety switch with coded RFID technology, developed to deliver high functional safety and reliable electromagnetic guard interlocking in industrial applications. Housed in a high-specification polyester enclosure and fitted with a QC-M12 connector for fast, simple installation, it is ideal for machine guarding systems that require secure guard monitoring and a high degree of tamper resistance.


  • Manufactured from high-specification polyester plastic
  • High-visibility LED indicator for clear device status
  • Holding force rated up to F1Max 1000N (100 kg)
  • Ingress protection up to IP67
  • Operates as a power-to-lock device

Part NumberDescriptionCoding Type
467006MGL-3P-M QC-M12 8wayMaster Coded (can be re-taught)
467003MGL-3P-U QC-M12 8wayUniquely Coded (cannot be re-taught)
467102MGL-3P Replacement ActuatorMaster Coded Only

Standards
ISO14119 EN60947-5-3 EN60204-1 ISO13849-1 UL508

Technical Specification
Dielectric Withstand250V.ac
Insulation Resistance100 Mohms
Switching DistanceSao 1mm Close Sar 10mm Open
Tolerance to Misalignment5mm in any direction from a gap of 5mm
Switching frequency1.0 Hz maximum
Contact Configuration2 N/C + 1 N/O, Voltage-Free Outputs
Approach speed200mm/m to 1000mm/s
Body materialPlastic
Temperature Range-25C to +40C
Enclosure ProtectionP67
Connection TypeM12 8-PIN
Mounting Bolts2 x M5 Tightening torque 2.0 Nm
Mounting PositionAny
Power Supply+24Vdc ± 10% (SELV / PELV)
Maximum Switched Current (outputs)200mA (Minimum internal resistance 8.5 Ohms)

Characteristic Data according to EN ISO13849-1
Performance Levele If both channels are used in combination with a SIL3/PLe control device
CategoryCat4
MTTFd1100a
Diagnostic Coverage DC99% (high)
Number of operating days per yeardop = 365d
Number of operating hours per dayhop = 24h
B10dNot mechanical parts implemented

Note
When the product is used deviant from these assumptions (different load, operating frequency, etc.) the values have to be adjusted accordingly.

INFORMATION WITH REGARD TO UL508
Type 1 Enclosures. Maximum temperature 40ºC. Maximum output 24V.dc 200mA. Powered by Class 2 or equivalent.